English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  An instrument for measurements of BrO with LED-based Cavity-Enhanced Differential Optical Absorption Spectroscopy

Hoch, D. J., Buxmann, J., Sihler, H., Pöhler, D., Zetzsch, C., & Platt, U. (2014). An instrument for measurements of BrO with LED-based Cavity-Enhanced Differential Optical Absorption Spectroscopy. Atmospheric Measurement Techniques, 7(1), 199-214. doi:10.5194/amt-7-199-2014.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Hoch, D. J.1, Author
Buxmann, J.1, Author
Sihler, H.2, Author           
Pöhler, D.1, Author
Zetzsch, C.1, Author
Platt, U.1, Author
Affiliations:
1external, ou_persistent22              
2Satellite Remote Sensing, Max Planck Institute for Chemistry, Max Planck Society, ou_1826293              

Content

show
hide
Free keywords: -
 Abstract: The chemistry of the troposphere and specifically the global tropospheric ozone budget is affected by reactive halogen species such as bromine monoxide (BrO) or chlorine monoxide (ClO). Especially BrO plays an important role in the processes of ozone destruction, disturbance of NOx and HOx chemistry, oxidation of dimethyl sulfide (DMS), and the deposition of elementary mercury. In the troposphere BrO has been detected in polar regions, at salt lakes, in volcanic plumes, and in the marine boundary layer. For a better understanding of these processes, field measurements as well as reaction chamber studies are performed. In both cases instruments with high spatial resolution and high sensitivity are necessary. A Cavity-Enhanced Differential Optical Absorption Spectroscopy (CE-DOAS) instrument with an open path measurement cell was designed and applied. For the first time, a CE-DOAS instrument is presented using an UV LED in the 325-365 nm wavelength range. In laboratory studies, BrO as well as HONO, HCHO, O-3, and O-4 could be reliably determined at detection limits of 20 ppt for BrO, 9.1 ppb for HCHO, 970 ppt for HONO, and 91 ppb for O-3, for five minutes integration time. The best detection limits were achieved for BrO (11 ppt), HCHO (5.1 ppb), HONO (490 ppt), and O-3 (59 ppb) for integration times of 81 minutes or less. Comparison with established White system (WS) DOAS and O-3 monitor measurements demonstrate the reliability of the instrument.

Details

show
hide
Language(s):
 Dates: 2014
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: ISI: 000330945400015
DOI: 10.5194/amt-7-199-2014
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Atmospheric Measurement Techniques
  Abbreviation : AMT
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Göttingen : European Geosciences Union, Copernicus
Pages: - Volume / Issue: 7 (1) Sequence Number: - Start / End Page: 199 - 214 Identifier: Other: 1867-1381
CoNE: https://pure.mpg.de/cone/journals/resource/1867-1381