Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  The removal of ocular artifacts from EEG signals: A comparison of performances for different methods

Klados, M., Papadelis, C., Lithari, C. D., & Bamidis, P. D. (2009). The removal of ocular artifacts from EEG signals: A comparison of performances for different methods. In 4th european conference of the international federation for medical and biological engineering (pp. 1259-1263). Springer.

Item is

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Klados, Manousos1, Autor           
Papadelis, C.1, Autor
Lithari, C. D.1, Autor
Bamidis, P. D.1, Autor
Affiliations:
1External Organizations, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: EOG; EEG; Artifacts; LMS; ICA
 Zusammenfassung: The presence of electrooculographic (EOG) artifacts in the electroencephalographic (EEG) signal is a major problem in the study of brain potentials. A variety of algorithms have been proposed to reject these artifacts including methods based on regression and blind source separation (BSS) techniques. None of them has so far been established as the method of choice. In the present study, the performances of five widely used EOG artifact rejection techniques are compared. The compared methodologies include two fully automated regression methods, one based on Least Mean Square (LMS) for its optimization process, and the other on Recursive Least Square (RLS) algorithm, two BSS techniques which use respectively the Extended — Independent Component Analysis (ext — ICA) and the Second Order Blind Identification (SOBI), and finally a time-varying adaptive algorithm based on H ∞ principles (H ∞ — TV). Each algorithm was applied in real EEG data and then their performance quantified in the time domain. The performance of RLS and H ∞ — TV were poor in removing eye — blink artifacts. For the rest of the methods the results supported the use of LMS technique and suggested the need for further research examining the performance of various artifact rejection techniques in both time and frequency domain.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2009
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1007/978-3-540-89208-3_300
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: 4th european conference of the international federation for medical and biological engineering
Genre der Quelle: Konferenzband
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Springer
Seiten: - Band / Heft: - Artikelnummer: - Start- / Endseite: 1259 - 1263 Identifikator: ISBN: 978-3-540-89207-6