  High-resolution ruby laser Thomson scattering diagnostic for the W7-AS stellarator

Knauer, J. P., Pasch, E., Kühner, G., & W7-AS Team (2003). High-resolution ruby laser Thomson scattering diagnostic for the W7-AS stellarator. Review of Scientific Instruments, 74, 1679-1682. doi:10.1063/1.1532766.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Knauer, J. P.1, Author           
Pasch, E.2, Author           
Kühner, G.3, Author           
W7-AS Team4, Author
Affiliations:
1External Organizations, ou_persistent22              
2Stellarator Optimisation (E3), Max Planck Institute for Plasma Physics, Max Planck Society, ou_1856329              
3Computer Center Garching (RZG), Max Planck Institute for Plasma Physics, Max Planck Society, ou_1856297              
4Max Planck Society, ou_persistent13              

Content

show
hide
Free keywords: -
 Abstract: After reconstruction, the ruby Thomson scattering diagnostic for the W7-AS stellarator is now in operation to again cover the complete plasma cross section (420 mm), where the former photomultiplier-based polychromator system has been replaced by two individual Littrow-type polychromator setups (focal length 50 cm), using intensified charge coupled device cameras for light detection. A single-pulse ruby laser with high pulse energy is used as a light source. The light scattered by the plasma electrons is imaged upon a set of 45 fiber bundles. 30 bundles provide a high spatial resolution of 4 mm at the inner edge of the plasma. The remaining part of the view chord is observed with a spatial resolution of 20 mm. At the output, the fiber bundles form the entrance slits of the Littrow-type spectrometers. The spectral resolution of the edge spectrometer can be modified by exchanging the diffraction grating. Depending on the installed diffraction grating (600 or 1800 lines/mm) a total wavelength range of 80 nm (suitable for plasma edge investigations) or 320 nm (suitable for gradient investigations) can be surveyed. The spectral intensity and geometrical calibration of the presented diagnostic setup can be done in situ by means of a neon spectral lamp and a calibrated tungsten strip lamp. The absolute sensitivity calibration for the system is achieved using either Raman (at 723.8 nm) or Rayleigh (at laser wavelength) scattering as hydrogen gas filled up in the vacuum vessel (up to 100 mbar). Examples of electron density and temperature profiles measured under different plasma conditions are presented.

Details

show
hide
Language(s): eng - English
 Dates: 2003
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Review of Scientific Instruments
  Alternative Title : Rev. Sci. Instrum.
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Copyright © 2003 American Institute of Physics
Pages: - Volume / Issue: 74 Sequence Number: - Start / End Page: 1679 - 1682 Identifier: -