Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Lasersysteme für die Präzisionsspektroskopie sympathetisch gekühlter hochgeladener Ionen

Feuchtenbeiner, S. (2015). Lasersysteme für die Präzisionsspektroskopie sympathetisch gekühlter hochgeladener Ionen. Master Thesis, Ruprecht-Karls-Universität, Heidelberg.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
Masterarbeit.pdf (Verlagsversion), 11MB
 
Datei-Permalink:
-
Name:
Masterarbeit.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Privat
MIME-Typ / Prüfsumme:
application/pdf
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Feuchtenbeiner, Stefanie1, Autor           
Affiliations:
1Division Prof. Dr. Thomas Pfeifer, MPI for Nuclear Physics, Max Planck Society, ou_2025284              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Cold, precisely localized highly charged ions are of particular interest for metrology and investigations of fundamental physics, such as possible drifts in the value of the fine structure constant alpha. Recently, it was possible to prepare Coulomb crystallized ultra-cold 40Ar13+-ions through sympathetic motional cooling in a cryogenic linear Paul trap [1]. For the spectroscopic investigation of the 2P3/2 - 2P1/2 M1 transition at 441nm in boronlike 40Ar13+ions sympathetically cooled to the mk-range, a tuneable Ti:Sa laser at 882nm with 100 kHz linewidth was built at the PTB. The laser setup including the frequency stabilization to a transfer cavity, which is locked to a Rubidium hyperfine transition using the Transfer-Modulation-Spectroscopy technique is presented. A first measurement of the MTS error signal is shown. For the sympathetic cooling of HCIs, 9Be+ is the coolant ion of choice. The cooling laser drives the 2S1/2 - 2P3/2 transition at 313 nm. For both precision spectroscopy of 40Ar13+and time dependent fluorescence measurements of 9Be+, power stabilization of the cooling laser is a necessary prerequisite. Therefor two intensity stabilization schemes were implemented and tested. Furthermore a setup for the determination of the Paul trap heating rate was built, which was tested by measuring the Doppler recooling times of a 0,5mm sized 9Be+ Coulombcrystal.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2015
 Publikationsstatus: Angenommen
 Seiten: II, 119 S. : Ill., graph. Darst.
 Ort, Verlag, Ausgabe: Heidelberg : Ruprecht-Karls-Universität
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: -
 Art des Abschluß: Master

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle

einblenden: