Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Feasibility of source images of computed tomographic angiography to detect the extent of ischemia in hyperacute stroke

Grond, M., Rudolf, J., Schneweis, S., Terstegge, K., Sobesky, J., Kracht, L., et al. (2002). Feasibility of source images of computed tomographic angiography to detect the extent of ischemia in hyperacute stroke. Cerebrovascular Diseases, 13(4), 251-256.

Item is

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Grond, Martin1, Autor
Rudolf, Jobst2, Autor           
Schneweis, Susanne1, Autor
Terstegge, K.1, Autor
Sobesky, Jan2, Autor           
Kracht, Lutz2, Autor           
Neveling, M.1, Autor
Heiss, Wolf-Dieter3, Autor           
Affiliations:
1Univ Cologne, Neurol Klin & Poliklin, Joseph Stelzmann Str 9,; D-50924 Cologne, Germany; Univ Cologne, Neurol Klin & Poliklin, D-50924 Cologne, Germany; Univ Cologne, Inst & Poliklin Radiol Diagnost, D-50924 Cologne, Germany; Max Planck Inst Neurol Res, D-50931 Cologne, Germany, ou_persistent22              
2Klinisches PET, Neurologische Abteilung, Max-Planck-Institut für neurologische Forschung, Managing Director: D. Yves von Cramon, Max Planck Institute for Metabolism Research, Managing Director: Jens Brüning, Max Planck Society, ou_2149663              
3Wolf-Dieter Heiss, Emeriti, Max Planck Institute for Metabolism Research, Managing Director: Jens Brüning, Max Planck Society, ou_2149649              

Inhalt

einblenden:
ausblenden:
Schlagwörter: ischemic stroke; computed tomographic angiography; positron emission tomography; transcranial Doppler sonography
 Zusammenfassung: Copyright 2002 S. Karger AG, Basel.
 Zusammenfassung: Background and Purpose: Computed tomographic angiography (CTA) is suggested to be a promising tool for patient selection for thrombolytic therapy of acute stroke. It does not only provide information on intracranial vasculature, but also on the capacity of the collateral circulation and the pattern of poorly perfused brain tissue. The objective of our study was to evaluate whether the presence and size of critically hypoperfused tissue assessed with flow positron emission tomography (PET) as a gold standard can reliably be identified on CTA source images. Methods: Fifteen potential candidates for early thrombolysis underwent CTA 65-170 min (mean 107 min) after the onset of acute anterior circulation stroke. Regional cerebral perfusion was measured between 27 and 86 min (mean 59 min) later with [O-15]-H2O and PET, and the volume of critically hypoperfused cortical tissue was assessed. CTA source images were evaluated by a neuroradiologist and an experienced stroke neurologist. The patients were classified into three groups according to the presumed size of the perfusion deficit on CTA (large, small, no perfusion deficit). Results: PET revealed the presence of critical cortical hypoperfusion in 10 patients, 5 had no critical cortical hypoperfusion. The neuroradiologist correctly identified the presence of a perfusion deficit in all patients, the neurologist had two false negative and one false positive ratings. Concerning the size of the perfusion deficit, there was considerable inaccuracy in both raters. Conclusions: The usefulness of CTA source images in yielding information about the perfusion state of stroke patients in clinical routine should not be overestimated.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2002
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: eDoc: 13388
ISI: 000176096400006
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Cerebrovascular Diseases
  Alternativer Titel : Cerebrovasc. Dis.
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 13 (4) Artikelnummer: - Start- / Endseite: 251 - 256 Identifikator: ISSN: 1015-9770