English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Navigator based respiratory gating during acquisition and preparation phases for proton liver spectroscopy at 3 T

Hock, A., Valkovic, L., Geier, A., Kuntzen, T., Boesiger, P., & Henning, A. (2014). Navigator based respiratory gating during acquisition and preparation phases for proton liver spectroscopy at 3 T. NMR in Biomedicine, 27(3), 348-355. doi:10.1002/nbm.3069.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Hock, A, Author
Valkovic, L, Author
Geier, A, Author
Kuntzen, T, Author
Boesiger, P, Author
Henning, A1, 2, Author           
Affiliations:
1Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              
2Research Group MR Spectroscopy and Ultra-High Field Methodology, Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_2528692              

Content

show
hide
Free keywords: -
 Abstract: Proton magnetic resonance spectroscopy (1H MRS) enables the non-invasive investigation of the human liver; however, because of technical difficulties it is not regularly used for diagnosis of liver diseases in clinical routine. Breathing motion is one of the major challenges, as it decreases spectral quality and leads to misplacement of the spectroscopic voxel. To overcome this problem, real-time navigator gating for spectral acquisition and preparation steps (B0 shimming, water frequency determination, receiver gain optimization, and water suppression) combined with short TE, optimized first order projection based B0 shimming, water suppression, and inner-volume saturated point resolved spectroscopy (PRESS) at 3 T is suggested. Simultaneous lipid and trimethylamine quantification is demonstrated by means of phantom, volunteer, and representative patient measurements. Precise localization of the voxel despite respiratory motion, increased spectral quality (higher signal-to-noise ratio and reduced linewidth) compared with measurements without respiratory gating, and the possibility of acquiring data without additional subject instructions regarding breathing enable robust and accurate liver 1H MRS measurements with this novel acquisition protocol.

Details

show
hide
Language(s):
 Dates: 2014-012014-03
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1002/nbm.3069
BibTex Citekey: HockVBH2013
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: NMR in Biomedicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 27 (3) Sequence Number: - Start / End Page: 348 - 355 Identifier: -