  A 16-channel dual-row transmit array in combination with a 31-element receive array for human brain imaging at 9.4 T

Shajan, G., Kozlov, M., Hoffmann, J., Turner, R., Scheffler, K., & Pohmann, R. (2014). A 16-channel dual-row transmit array in combination with a 31-element receive array for human brain imaging at 9.4 T. Magnetic Resonance in Medicine, 71(2), 870-879. doi:10.1002/mrm.24726.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Shajan, G1, 2, Autor           
Kozlov, M, Autor
Hoffmann, J1, 2, Autor           
Turner, R, Autor
Scheffler, K1, 2, Autor           
Pohmann, R1, 2, Autor           
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Purpose
Arranging transmit array elements in multiple rows provides an additional degree of freedom to correct B1+ field inhomogeneities and to achieve whole-brain excitation at ultrahigh field strengths. Receive arrays shaped to the contours of the anatomy increase the signal-to-noise ratio of the image. In this work, the advantages offered by the transmit and receive array techniques are combined for human brain imaging at 9.4 T.
Methods
A 16-element dual-row transmit array and a 31-element receive array were developed. Based on an accurate numerical model of the transmit array, the deposited power was calculated for different head sizes and positions. The influence of the receive array on the transmit field was characterized. Parallel imaging performance and signal-to-noise ratio of the receive array were evaluated.
Results
On average, a two fold increase in signal-to-noise ratio was observed in the whole-brain volume when compared with a 16-channel elliptic microstrip transceiver array. The benefits of combining the two arrays, B1+ shimming in three directions and high receive sensitivity, are demonstrated with high-resolution in vivo images.
Conclusion
The dual-row transmit array provides whole-brain coverage at 9.4 T, which, in combination with the helmet-shaped receive array, is a valuable radio frequency configuration for ultra-high field magnetic resonance imaging of the human brain.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2013-032014-02
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1002/mrm.24726
BibTex Citekey: ShajanKHTSP2013
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance in Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: New York : Wiley-Liss
Seiten: - Band / Heft: 71 (2) Artikelnummer: - Start- / Endseite: 870 - 879 Identifikator: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149