日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

登録内容を編集ファイル形式で保存
 
 
ダウンロード電子メール
  A 16-channel dual-row transmit array in combination with a 31-element receive array for human brain imaging at 9.4 T

Shajan, G., Kozlov, M., Hoffmann, J., Turner, R., Scheffler, K., & Pohmann, R. (2014). A 16-channel dual-row transmit array in combination with a 31-element receive array for human brain imaging at 9.4 T. Magnetic Resonance in Medicine, 71(2), 870-879. doi:10.1002/mrm.24726.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Shajan, G1, 2, 著者           
Kozlov, M, 著者
Hoffmann, J1, 2, 著者           
Turner, R, 著者
Scheffler, K1, 2, 著者           
Pohmann, R1, 2, 著者           
所属:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

内容説明

表示:
非表示:
キーワード: -
 要旨: Purpose
Arranging transmit array elements in multiple rows provides an additional degree of freedom to correct B1+ field inhomogeneities and to achieve whole-brain excitation at ultrahigh field strengths. Receive arrays shaped to the contours of the anatomy increase the signal-to-noise ratio of the image. In this work, the advantages offered by the transmit and receive array techniques are combined for human brain imaging at 9.4 T.
Methods
A 16-element dual-row transmit array and a 31-element receive array were developed. Based on an accurate numerical model of the transmit array, the deposited power was calculated for different head sizes and positions. The influence of the receive array on the transmit field was characterized. Parallel imaging performance and signal-to-noise ratio of the receive array were evaluated.
Results
On average, a two fold increase in signal-to-noise ratio was observed in the whole-brain volume when compared with a 16-channel elliptic microstrip transceiver array. The benefits of combining the two arrays, B1+ shimming in three directions and high receive sensitivity, are demonstrated with high-resolution in vivo images.
Conclusion
The dual-row transmit array provides whole-brain coverage at 9.4 T, which, in combination with the helmet-shaped receive array, is a valuable radio frequency configuration for ultra-high field magnetic resonance imaging of the human brain.

資料詳細

表示:
非表示:
言語:
 日付: 2013-032014-02
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): DOI: 10.1002/mrm.24726
BibTex参照ID: ShajanKHTSP2013
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Magnetic Resonance in Medicine
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: New York : Wiley-Liss
ページ: - 巻号: 71 (2) 通巻号: - 開始・終了ページ: 870 - 879 識別子(ISBN, ISSN, DOIなど): ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149