日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  Diffusion properties of conventional and calcium-sensitive MRI contrast agents in the rat cerebral cortex

Hagberg, G., Mamedov, I., Power, A., Beyerlein, M., Merkle, H., Kiselev, V., Dhingra, K., Kubiček, V., Angelovski, G., & Logothetis, N. (2014). Diffusion properties of conventional and calcium-sensitive MRI contrast agents in the rat cerebral cortex. Contrast Media Molecular Imaging, 9(1), 71-82. doi:10.1002/cmmi.1535.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:
非表示:
説明:
-
OA-Status:

作成者

表示:
非表示:
 作成者:
Hagberg, G1, 2, 著者           
Mamedov, I2, 3, 著者           
Power, A2, 3, 著者           
Beyerlein, M2, 3, 著者           
Merkle, H, 著者           
Kiselev, VG, 著者
Dhingra, K2, 3, 著者           
Kubiček, V, 著者
Angelovski, G2, 4, 著者           
Logothetis, NK2, 3, 著者           
所属:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              
3Department Physiology of Cognitive Processes, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497798              
4Research Group MR Neuroimaging Agents, Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_2528691              

内容説明

表示:
非表示:
キーワード: -
 要旨: Calcium-sensitive MRI contrast agents can only yield quantitative results if the agent concentration in the tissue is known. The agent concentration could be determined by diffusion modeling, if relevant parameters were available. We have established an MRI-based method capable of determining diffusion properties of conventional and calcium-sensitive agents. Simulations and experiments demonstrate that the method is applicable both for conventional contrast agents with a fixed relaxivity value and for calcium-sensitive contrast agents. The full pharmacokinetic time-course of gadolinium concentration estimates was observed by MRI before, during and after intracerebral administration of the agent, and the effective diffusion coefficient D* was determined by voxel-wise fitting of the solution to the diffusion equation. The method yielded whole brain coverage with a high spatial and temporal sampling. The use of two types of MRI sequences for sampling of the diffusion time courses was investigated: Lookndash;Locker-based quantitative T1 mapping, and T1-weighted MRI. The observation times of the proposed MRI method is long (up to 20thinsp;h) and consequently the diffusion distances covered are also long (2ndash;4thinsp;mm). Despite this difference, the D* values in vivo were in agreement with previous findings using optical measurement techniques, based on observation times of a few minutes. The effective diffusion coefficient determined for the calcium-sensitive contrast agents may be used to determine local tissue concentrations and to design infusion protocols that maintain the agent concentration at a steady state, thereby enabling quantitative sensing of the local calcium concentration.

資料詳細

表示:
非表示:
言語:
 日付: 2014-01
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): DOI: 10.1002/cmmi.1535
BibTex参照ID: HagbergMPBMVKDKL2013
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Contrast Media Molecular Imaging
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 9 (1) 通巻号: - 開始・終了ページ: 71 - 82 識別子(ISBN, ISSN, DOIなど): -