English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Orthogonalizing crusher and diffusion-encoding gradients to suppress undesired echo pathways in the twice-refocused spin echo diffusion sequence

Nagy, Z., Thomas, D. L., & Weiskopf, N. (2014). Orthogonalizing crusher and diffusion-encoding gradients to suppress undesired echo pathways in the twice-refocused spin echo diffusion sequence. Magnetic Resonance in Medicine, 71(2), 506-515. doi:10.1002/mrm.24676.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Nagy, Zoltan1, Author
Thomas, David L.2, Author
Weiskopf, Nikolaus1, Author           
Affiliations:
1Wellcome Trust Centre for Neuroimaging, University College London, United Kingdom, ou_persistent22              
2Department of Brain Repair & Rehabilitation, Institute of Neurology, University College London, United Kingdom, ou_persistent22              

Content

show
hide
Free keywords: Diffusion tensor imaging; TRSE; Crusher gradients; Artifact
 Abstract: PURPOSE:

The twice-refocused spin echo sequence is widely used in diffusion imaging due to its excellent performance in reducing eddy currents. The three radio frequency pulses give rise to eight separate signal pathways. Because there is no general solution for the size and arrangement for crusher gradients, with constant size and orientation, that is effective for all arbitrary diffusion-sensitizing b-values and directions, this article introduces and validates a solution whereby the crusher and diffusion-encoding gradients are always kept orthogonal, thus ensuring their independence.
METHODS:

The cancellation of the crusher and diffusion gradients was demonstrated. Subsequently, crusher gradients were implemented in such a way that they were always orthogonal to the diffusion gradient. Phantom and in-vivo experiments were performed to ascertain that orthogonally implemented crusher gradients alleviate the problem without lowering image quality.
RESULTS:

In all experiments, when the crusher gradients' action was cancelled by the diffusion-encoding gradients artifactual signal modulation was observed. When orthogonal gradients were implemented the artifacts were eliminated without detrimental effects on image quality.
CONCLUSIONS:

Orthogonal crushers are easy to implement and can be used for any variant of diffusion imaging sequences (e.g., diffusion tensor imaging, fiber diameter mapping) where the twice-refocused scheme is used.

Details

show
hide
Language(s): eng - English
 Dates: 2013-02-132014-02-01
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1002/mrm.24676
PMID: 23440863
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 71 (2) Sequence Number: - Start / End Page: 506 - 515 Identifier: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149