English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Zero-loss image formation and modified contrast transfer theory in EFTEM

Angert, I., Majorovits, E., & Schröder, R. R. (2000). Zero-loss image formation and modified contrast transfer theory in EFTEM. Ultramicroscopy, 81(3), 203-222. doi:10.1016/S0304-3991(99)00190-4.

Item is

Basic

show hide
Genre: Journal Article
Alternative Title : Zero-loss image formation and modified contrast transfer theory in EFTEM

Files

show Files
hide Files
:
Ultramicroscopy_81_2000_203.pdf (Any fulltext), 918KB
 
File Permalink:
-
Name:
Ultramicroscopy_81_2000_203.pdf
Description:
-
OA-Status:
Visibility:
Restricted (Max Planck Institute for Medical Research, MHMF; )
MIME-Type / Checksum:
application/pdf
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Creators

show
hide
 Creators:
Angert, Isabel1, Author           
Majorovits, Endre1, Author           
Schröder, Rasmus R.1, Author           
Affiliations:
1Emeritus Group Biophysics, Max Planck Institute for Medical Research, Max Planck Society, ou_1497712              

Content

show
hide
Free keywords: Zero-loss imaging; EFTEM; CTF; Filter contrast
 Abstract: For a weak phase/weak amplitude object the information transfer in the imaging process of TEM is described by the common formalism of the contrast transfer function (CTF). So far the effects of inelastic scattering were not accounted for in this formalism. In conventional imaging they were simply neglected. In energy filtering TEM (EFTEM), where removal of inelastic electrons leads to higher specimen contrast, they were modelled by a global increase of the elastic amplitude contrast. Thus, the description of inelastic and elastic scattering was mixed. Here a new ansatz is proposed which treats elastic and inelastic contrast transfer separately by adding an inelastic contribution to the scattering potentials. In EFTEM this has the effect of adding a filter contrast which depends on the characteristics of the inelastic scattering. For samples with dominant plasmon loss the additional filter contrast is restricted to low resolution. Because of its strong dependence on the nature of the inelastic scattering process, the filter contrast cannot in general be unified with the conventional elastic amplitude contrast. The modified CTF theory for EFTEM was tested experimentally on a variety of samples. Images of amorphous layers of copper, aluminium, and carbon films, as well as zero-loss images of proteins embedded in amorphous ice were evaluated. The values of the parameters of the additional filter contrast were determined for carbon film and proteins embedded in vitrified ice. Comparison of different CTF models used to reconstruct 3D volumes from zero-loss images confirmed that best agreement with the atomic model is attained with the new, modified CTF theory

Details

show
hide
Language(s): eng - English
 Dates: 1999-07-281999-10-042000-04-072000-04-01
 Publication Status: Issued
 Pages: 20
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Ultramicroscopy
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Amsterdam : North-Holland
Pages: - Volume / Issue: 81 (3) Sequence Number: - Start / End Page: 203 - 222 Identifier: ISSN: 0304-3991
CoNE: https://pure.mpg.de/cone/journals/resource/954925512451