  Phase informed model for motion and susceptibility

Hutton, C., Andersson, J., Deichmann, R., & Weiskopf, N. (2013). Phase informed model for motion and susceptibility. Human Brain Mapping, 34(11), 3086-3100. doi:10.1002/hbm.22126.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
Hutton_Andersson_2013.pdf (Verlagsversion), 2MB
Name:
Hutton_Andersson_2013.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Hutton, Chloe1, Autor
Andersson, Jesper2, Autor
Deichmann, Ralf3, Autor
Weiskopf, Nikolaus1, Autor           
Affiliations:
1Wellcome Trust Centre for Neuroimaging, University College London, United Kingdom, ou_persistent22              
2FMRIB Centre, University of Oxford, United Kingdom, ou_persistent22              
3Brain Imaging Centre, Goethe University, Frankfurt, Germany, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: EPI; Distortion correction; Dynamic field mapping; Head motion; Phase image; Susceptibility artifact
 Zusammenfassung: Field inhomogeneities caused by variations in magnetic susceptibility throughout the head lead to geometric distortions, mainly in the phase-encode direction of echo-planar images (EPI). The magnitude and spatial characteristics of the distortions depend on the orientation of the head in the magnetic field and will therefore vary with head movement. A new method is presented, based on a phase informed model for motion and susceptibility (PIMMS), which estimates the change in geometric distortion associated with head motion. This method fits a model of the head motion parameters and scanner hardware characteristics to EPI phase time series. The resulting maps of the model fit parameters are used to correct for susceptibility artifacts in the magnitude images. Results are shown for EPI-based fMRI time-series acquired at 3T, demonstrating that compared with conventional rigid body realignment, PIMMS removes residual variance associated with motion-related distortion effects. Furthermore, PIMMS can lead to a reduction in false negatives compared with the widely accepted approach which uses standard rigid body realignment and includes the head motion parameters in the statistical model. The PIMMS method can be used with any standard EPI sequence for which accurate phase information is available.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2012-03-152011-05-032012-04-202012-06-272013-11
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1002/hbm.22126
PMID: 22736546
Anderer: Epub 2012
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Human Brain Mapping
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 34 (11) Artikelnummer: - Start- / Endseite: 3086 - 3100 Identifikator: ISSN: 1065-9471
CoNE: https://pure.mpg.de/cone/journals/resource/954925601686