English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Spoiling without additional gradients: Radial FLASH MRI with randomized radiofrequency phases.

Roeloffs, V. B., Voit, D., & Frahm, J. (2016). Spoiling without additional gradients: Radial FLASH MRI with randomized radiofrequency phases. Magnetic Resonance in Medicine, 75(5), 2094-2099. doi:10.1002/mrm.25809.

Item is

Files

show Files
hide Files
:
2167638.pdf (Publisher version), 3MB
 
File Permalink:
-
Name:
2167638.pdf
Description:
-
OA-Status:
Visibility:
Restricted (UNKNOWN id 303; )
MIME-Type / Checksum:
application/pdf
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show
hide
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Roeloffs, V. B.1, Author           
Voit, D.1, Author           
Frahm, J.1, Author           
Affiliations:
1Biomedical NMR Research GmbH, MPI for Biophysical Chemistry, Max Planck Society, ou_578634              

Content

show
hide
Free keywords: RF spoiling; gradient spoiling; Golden Angle; radial MRI; real-time MRI
 Abstract: Purpose To develop a method for spoiling transverse magnetizations without additional gradients to minimize repetition times for radial fast low angle shot (FLASH) MRI. Methods Residual steady state transverse magnetizations and corresponding image artifacts were analyzed for radial gradient echo sequences with constant and randomized RF phases in comparison with a sequence with refocused frequency-encoding gradients, constant spoiler gradient, and conventional RF spoiling (gold standard). The spoiling performance was assessed for different radial trajectories using numerical simulations, phantom experiments, and in vivo MRI studies of the human brain. Results Simulations as well as phantom and in vivo measurements reveal a highly efficient spoiling capacity for randomized RF phases and radial FLASH sequences without the need for gradient rewinding and spoiler gradients. The data also demonstrate a strong dependence of the spoiling performance on the chosen radial trajectory (ie, the azimuthal angular increment between successive projections) with excellent results for an interleaved multiturn scheme. Conclusion Effective spoiling of transverse magnetizations in radial FLASH MRI may be achieved by randomized RF phases without additional spoiler gradients. The technique allows for short repetition times as required for high-speed real-time MRI.

Details

show
hide
Language(s): eng - English
 Dates: 2015-06-222016-05
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1002/mrm.25809
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 75 (5) Sequence Number: - Start / End Page: 2094 - 2099 Identifier: -