  A comparison of two sleep spindle detection methods based on all night averages: individually adjusted vs. fixed frequencies

Ujma, P. P., Gombos, F., Genzel, L., Konrad, B. N., Simor, P., Steiger, A., Dresler, M., & Bodizs, R. (2015). A comparison of two sleep spindle detection methods based on all night averages: individually adjusted vs. fixed frequencies. FRONTIERS IN HUMAN NEUROSCIENCE, 9:. doi:10.3389/fnhum.2015.00052.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル
非表示: ファイル
:
fnhum-09-00052.pdf (全文テキスト(全般)), 4MB
ファイルのパーマリンク:
https://hdl.handle.net/11858/00-001M-0000-0028-F4F0-5
ファイル名:
fnhum-09-00052.pdf
説明:
-
OA-Status:
閲覧制限:
公開
MIMEタイプ / チェックサム:
application/pdf / [MD5]
技術的なメタデータ:
著作権日付:
-
著作権情報:
-

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Ujma, Peter Przemyslaw1, 著者
Gombos, Ferenc1, 著者
Genzel, Lisa1, 著者
Konrad, Boris Nikolai2, 著者           
Simor, Peter1, 著者
Steiger, Axel2, 著者           
Dresler, Martin1, 2, 著者           
Bodizs, Robert1, 著者
所属:
1external, ou_persistent22              
2Dept. Clinical Research, Max Planck Institute of Psychiatry, Max Planck Society, ou_2035296              

内容説明

表示:
非表示:
キーワード: EEG, sleep spindles, sigma waves, automatic detection, fixed frequenca mehtod, IAM, comparison
 要旨: Sleep spindles are frequently studied for their relationship with state and trait cognitive variables, and they are thought to play an important role in sleep-related memory consolidation. Due to their frequent occurrence in NREM sleep, the detection of sleep spindles is only feasible using automatic algorithms, of which a large number is available. We compared subject averages of the spindle parameters computed by a fixed frequency (FixF) (11-13 Hz for slow spindles, 13-15 Hz for fast spindles) automatic detection algorithm and the individual adjustment method (IAM), which uses individual frequency bands for sleep spindle detection. Fast spindle duration and amplitude are strongly correlated in the two algorithms, but there is little overlap in fast spindle density and slow spindle parameters in general. The agreement between fixed and manually determined sleep spindle frequencies is limited, especially in case of slow spindles. This is the most likely reason for the poor agreement between the two detection methods in case of slow spindle parameters. Our results suggest that while various algorithms may reliably detect fast spindles, a more sophisticated algorithm primed to individual spindle frequencies is necessary for the detection of slow spindles as well as individual variations in the number of spindles in general.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2015-02-17
 出版の状態: オンラインで出版済み
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): ISI: 000349433400001
DOI: 10.3389/fnhum.2015.00052
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: FRONTIERS IN HUMAN NEUROSCIENCE
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -