  Evaluation of 2D multiband EPI imaging for high-resolution, whole-brain, task-based fMRI studies at 3T: Sensitivity and slice leakage artifacts

Todd, N., Moeller, S., Auerbach, E. J., Yacoub, E., Flandin, G., & Weiskopf, N. (2016). Evaluation of 2D multiband EPI imaging for high-resolution, whole-brain, task-based fMRI studies at 3T: Sensitivity and slice leakage artifacts. NeuroImage, 124(A), 32-42. doi:10.1016/j.neuroimage.2015.08.056.

Item is

Files

show Files
hide Files
:
Todd_Moeller_2015.pdf (Publisher version), 3MB
Name:
Todd_Moeller_2015.pdf
Description:
-
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show

Creators

show
hide
 Creators:
Todd, Nick1, Author
Moeller, Steen2, Author
Auerbach, Edward J.2, Author
Yacoub, Essa2, Author
Flandin, Guillaume1, Author
Weiskopf, Nikolaus1, 3, Author           
Affiliations:
1Wellcome Trust Centre for Neuroimaging, University College London, United Kingdom, ou_persistent22              
2Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN, USA, ou_persistent22              
3Department Neurophysics (Weiskopf), MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_2205649              

Content

show
hide
Free keywords: High resolution; Multiband excitation; Simultaneous multislice; Whole brain; fMRI
 Abstract: Functional magnetic resonance imaging (fMRI) studies that require high-resolution whole-brain coverage have long scan times that are primarily driven by the large number of thin slices acquired. Two-dimensional multiband echo-planar imaging (EPI) sequences accelerate the data acquisition along the slice direction and therefore represent an attractive approach to such studies by improving the temporal resolution without sacrificing spatial resolution. In this work, a 2D multiband EPI sequence was optimized for 1.5mm isotropic whole-brain acquisitions at 3T with 10 healthy volunteers imaged while performing simultaneous visual and motor tasks. The performance of the sequence was evaluated in terms of BOLD sensitivity and false-positive activation at multiband (MB) factors of 1, 2, 4, and 6, combined with in-plane GRAPPA acceleration of 2× (GRAPPA 2), and the two reconstruction approaches of Slice-GRAPPA and Split Slice-GRAPPA. Sensitivity results demonstrate significant gains in temporal signal-to-noise ratio (tSNR) and t-score statistics for MB 2, 4, and 6 compared to MB 1. The MB factor for optimal sensitivity varied depending on anatomical location and reconstruction method. When using Slice-GRAPPA reconstruction, evidence of false-positive activation due to signal leakage between simultaneously excited slices was seen in one instance, 35 instances, and 70 instances over the ten volunteers for the respective accelerations of MB 2×GRAPPA 2, MB 4×GRAPPA 2, and MB 6×GRAPPA 2. The use of Split Slice-GRAPPA reconstruction suppressed the prevalence of false positives significantly, to 1 instance, 5 instances, and 5 instances for the same respective acceleration factors. Imaging protocols using an acceleration factor of MB 2×GRAPPA 2 can be confidently used for high-resolution whole-brain imaging to improve BOLD sensitivity with very low probability for false-positive activation due to slice leakage. Imaging protocols using higher acceleration factors (MB 3 or MB

Details

show
hide
Language(s): eng - English
 Dates: 2015-02-252015-08-252015-09-012016-01-01
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1016/j.neuroimage.2015.08.056
PMID: 26341029
PMC: PMC4655914
Other: Epub 2015
 Degree: -

Event

show

Legal Case

show

Project information

show hide
Project name : Non-invasive in vivo histology in health and disease using Magnetic Resonance Imaging (MRI) / HMRI
Grant ID : 616905
Funding program : FP7 (ERC-2013-CoG)
Funding organization : European Research Council
Project name : -
Grant ID : -
Funding program : -
Funding organization : SLMS Capital Equipment Fund (UCL)
Project name : -
Grant ID : -
Funding program : -
Funding organization : Wellcome Trust

Source 1

show
hide
Title: NeuroImage
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Orlando, FL : Academic Press
Pages: - Volume / Issue: 124 (A) Sequence Number: - Start / End Page: 32 - 42 Identifier: ISSN: 1053-8119
CoNE: https://pure.mpg.de/cone/journals/resource/954922650166