  A method for improving the performance of gradient systems for diffusion-weighted MRI

Nagy, Z., Weiskopf, N., Alexander, D. C., & Deichmann, R. (2007). A method for improving the performance of gradient systems for diffusion-weighted MRI. Magnetic Resonance in Medicine, 58(4), 763-768. doi:10.1002/mrm.21379.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Nagy, Zoltan1, Author
Weiskopf, Nikolaus1, Author           
Alexander, Daniel C.2, Author
Deichmann, Ralph1, 3, Author
Affiliations:
1Wellcome Trust Centre for Neuroimaging, University College London, United Kingdom, ou_persistent22              
2Centre for Medical Image Computing, University College London, United Kingdom, ou_persistent22              
3Brain Imaging Centre, Goethe University, Frankfurt, Germany, ou_persistent22              

Content

show
hide
Free keywords: Diffusion tensor imaging; Apparent diffusion constant; Magnetic field gradient; Fibre tracking; Anisotropy
 Abstract: The MR signal is sensitive to diffusion. This effect can be increased by the use of large, balanced bipolar gradients. The gradient systems of MR scanners are calibrated at installation and during regular servicing visits. Because the measured apparent diffusion constant (ADC) depends on the square of the amplitude of the diffusion sensitizing gradients, errors in the gradient calibration are exaggerated. If the error is varying among the different gradient axes, it will affect the estimated degree of anisotropy. To assess the gradient calibration accuracy in a whole-body MRI scanner, ADC values were calculated for a uniform water phantom along each gradient direction while monitoring the temperature. Knowledge of the temperature allows the expected diffusion constant of water to be calculated independent of the MRI measurement. It was found that the gradient axes (+/-x, +/-y, +/-z) were calibrated differently, resulting in offset ADC values. A method is presented to rescale the amplitude of each of the six principal gradient axes within the MR pulse sequence. The scaling factor is the square root of the ratio of the expected and observed diffusion constants. In addition, fiber tracking results in the human brain were noticeably affected by improving the gradient system calibration.

Details

show
hide
Language(s): eng - English
 Dates: 2007-09-272007-10-01
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1002/mrm.21379
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 58 (4) Sequence Number: - Start / End Page: 763 - 768 Identifier: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149