Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Study on modified point contact germanium detectors for low background applications

Salathe, M. (2015). Study on modified point contact germanium detectors for low background applications. PhD Thesis, Ruprecht-Karls-Universität, Heidelberg.

Item is

Dateien

ausblenden: Dateien
:
Dissertation_MarcoSalathe.pdf (beliebiger Volltext), 3MB
Name:
Dissertation_MarcoSalathe.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

ausblenden:
 Urheber:
Salathe, Marco1, Autor           
Lindner, Manfred, Gutachter
Herrmann, Norbert, Gutachter
Affiliations:
1Division Prof. Dr. Manfred Lindner, MPI for Nuclear Physics, Max Planck Society, ou_904549              

Inhalt

ausblenden:
Schlagwörter: -
 Zusammenfassung: Point contact germanium (PCGe) detectors play a vital role in research such as, neutrinoless double beta decay, direct dark matter detection, the neutrino magnetic moment and coherent neutrino-nucleus scattering. This dissertation presents an experimental investigation of two commercially available, almost identical large volume PCGe detectors (~760 g). Their point contact size was stepwise modified according to specified simulations of the electric field in the detectors. The reduction of the point contact size improved both, the pulse shape discrimination efficiency of background signals at a few MeV and the noise from electronics. The lowest contribution of noise to the energy resolution was (299 ± 2) eV and (336 ±2) eV (FWHM) for the two detectors, respectively. The better value translates to an energy threshold of 1 keV for an experiment with a low background level. A sensitivity study concluded that a resolution of less than 150 - 180 eV is required to detect the coherent neutrino-nucleus scattering near nuclear reactors. This is a factor of two better than the currently obtained value. Additionally, two different approaches have been used to determine the Fano factor. They both yielded consistent results, the better result is 0.1076 ± 0.0005. Before the most optimal results could be obtained, an evaluation of three shaping filters (the rounded-top cusp, rounded-top trapezoidal and Gaussian filter) and a ballistic deficit correction was performed. Once completed the most ideal combinations of filters were used to procure the dissertation's findings.

Details

ausblenden:
Sprache(n):
 Datum: 2015-11-25
 Publikationsstatus: Angenommen
 Seiten: 154 S. : Ill., graph. Darst.
 Ort, Verlag, Ausgabe: Heidelberg : Ruprecht-Karls-Universität
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.17617/2.2241924
 Art des Abschluß: Doktorarbeit

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle

einblenden: