  Diffraction tomography and Rietveld refinement of a hydroxyapatite bone phantom

Frølich, S., Leemreize, H., Jakus, A., Xiao, X., Shah, R., Birkedal, H., et al. (2016). Diffraction tomography and Rietveld refinement of a hydroxyapatite bone phantom. Journal of Applied Crystallography, 49(1), 103-109. doi:10.1107/S1600576715022633.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
2242198.pdf (Verlagsversion), 2MB
 
Datei-Permalink:
-
Name:
2242198.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Eingeschränkt (Max Planck Institute of Colloids and Interfaces, MTKG; )
MIME-Typ / Prüfsumme:
application/pdf
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Frølich, S., Autor
Leemreize, H.1, Autor           
Jakus, A., Autor
Xiao, X., Autor
Shah, R., Autor           
Birkedal, H., Autor
Almer, J. D., Autor
Stock, S. R., Autor
Affiliations:
1Yael Politi, Biomaterialien, Max Planck Institute of Colloids and Interfaces, Max Planck Society, ou_1863297              

Inhalt

einblenden:
ausblenden:
Schlagwörter: X-ray diffraction tomography, Rietveld refinement, hydroxyapatite, bone
 Zusammenfassung: A model sample consisting of two different hydroxyapatite (hAp) powders was used as a bone phantom to investigate the extent to which X-ray diffraction tomography could map differences in hAp lattice constants and crystallite size. The diffraction data were collected at beamline 1-ID, the Advanced Photon Source, using monochromatic 65 keV X-radiation, a 25 x 25 microm pinhole beam and translation/rotation data collection. The diffraction pattern was reconstructed for each volume element (voxel) in the sample, and Rietveld refinement was used to determine the hAp lattice constants. The crystallite size for each voxel was also determined from the 00.2 hAp diffraction peak width. The results clearly show that differences between hAp powders could be measured with diffraction tomography.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2016
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1107/S1600576715022633
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Journal of Applied Crystallography
  Kurztitel : J. Appl. Cryst.
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Oxford : Blackwell
Seiten: - Band / Heft: 49 (1) Artikelnummer: - Start- / Endseite: 103 - 109 Identifikator: ISSN: 0021-8898