日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

登録内容を編集ファイル形式で保存
 
 
ダウンロード電子メール
  Baseline oxygenation in the brain: Correlation between respiratory-calibration and susceptibility methods

Fan, A. P., Schäfer, A., Huber, L., Lampe, L., von Smuda, S., Möller, H. E., Villringer, A., & Gauthier, C. (2016). Baseline oxygenation in the brain: Correlation between respiratory-calibration and susceptibility methods. NeuroImage, 125, 920-931. doi:10.1016/j.neuroimage.2015.11.007.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Fan, Audrey P.1, 2, 著者
Schäfer, Andreas1, 著者           
Huber, Laurentius3, 著者           
Lampe, Leonie4, 著者           
von Smuda, Steffen3, 著者           
Möller, Harald E.3, 著者           
Villringer, Arno4, 著者           
Gauthier, Claudine4, 5, 著者           
所属:
1Department Neurophysics (Weiskopf), MPI for Human Cognitive and Brain Sciences, Max Planck Society, Leipzig, DE, ou_2205649              
2Richard M. Lucas Service Center for Imaging, Stanford University, CA, USA, ou_persistent22              
3Methods and Development Unit Nuclear Magnetic Resonance, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634558              
4Department Neurology, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634549              
5Concordia University, Montréal, QC, Canada, ou_persistent22              

内容説明

表示:
非表示:
キーワード: Brain oxygenation; Oxygen extraction fraction; Quantitative susceptibility mapping; Calibrated BOLD; Magnetic resonance imaging
 要旨: New MRI methods for noninvasive imaging of baseline oxygen extraction fraction (OEF) in the brain show great promise. Quantitative O2 imaging (QUO2) applies a biophysical model to measure OEF in tissue from BOLD, cerebral blood flow (CBF), and end-tidal O2 (ETO2) signals acquired during two or more gas manipulations. Alternatively, quantitative susceptibility mapping (QSM) maps baseline OEF along cerebral vessels based on the deoxyhemoblogin (dHb) susceptibility shift between veins and water. However, these approaches have not been carefully compared to each other or to known physiological signals. The aims of this study were to compare OEF values by QUO2 and QSM; and to see if baseline OEF relates to BOLD and CBF changes during a visual task.

Simultaneous BOLD and arterial spin labeling (ASL) scans were acquired at 7 T in 11 healthy subjects continuously during hypercapnia (5% CO2, 21% O2), hyperoxia (100% O2), and carbogen (5% CO2, 95% O2) for QUO2 analysis. Separate BOLD-ASL scans were acquired during a checkerboard stimulus to identify functional changes in the visual cortex. Gradient echo phase images were also collected at rest for QSM reconstruction of OEF along cerebral veins draining the visual cortex.

Mean baseline OEF was (43.5 ± 14)% for QUO2 with two gases, (42.3 ± 17)% for QUO2 with three gases, and (29.4 ± 3)% for QSM across volunteers. Three-gas QUO2 values of OEF correlated with QSM values of OEF (P = 0.03). However, Bland–Altman analysis revealed that QUO2 tended to measure higher baseline OEF with respect to QSM, which likely results from underestimation of the hyperoxic BOLD signal and low signal-to-noise ratio of the ASL acquisitions. Across subjects, the percent CBF change during the visual task correlated with OEF measured by 3-gas QUO2 (P < 0.04); and by QSM (P = 0.035), providing evidence that the new methods measure true variations in brain physiology across subjects.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2015-07-102015-11-032015-11-052016-01-15
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: 査読あり
 識別子(DOI, ISBNなど): DOI: 10.1016/j.neuroimage.2015.11.007
PMID: 26549301
その他: Epub 2015
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: NeuroImage
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: Orlando, FL : Academic Press
ページ: - 巻号: 125 通巻号: - 開始・終了ページ: 920 - 931 識別子(ISBN, ISSN, DOIなど): ISSN: 1053-8119
CoNE: https://pure.mpg.de/cone/journals/resource/954922650166