English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  The design, implementation, and testing of a sensorized MRI-compatible cello

Hollinger, A., & Wanderley, M. M. (2015). The design, implementation, and testing of a sensorized MRI-compatible cello. IEEE Sensors Journal, 15(11), 6125-6134. doi:10.1109/JSEN.2015.2449876.

Item is

Files

show Files

Locators

show
hide
Locator:
https://ieeexplore.ieee.org/document/7134701 (Publisher version)
Description:
-
OA-Status:
Green

Creators

show
hide
 Creators:
Hollinger, Avrum1, Author           
Wanderley, Marcelo M.2, Author
Affiliations:
1MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634548              
2Schulich School of Music, McGill University, Montréal, Canada, ou_persistent22              

Content

show
hide
Free keywords: Fibre optic sensors; MRI-compatible interface; Musical performance gestures
 Abstract: The design and testing of optical sensors for a cello compatible with magnetic resonance imaging (MRI) are presented. The interface is used in neuroimaging experiments, allowing for the first time, the acquisition of cello performance gestures captured inside the MRI scanner. Left-hand fingering and right-hand bowing gestures were captured with optical sensors embedded in the fingerboard, bridge, and bow. Finger-string interaction was sensed through diffuse reflection using plastic optical fibres potted in a 3D-printed fingerboard. Acoustic string vibration was sensed through the transmissive amplitude modulation of an emitting-receiving fibre pair mounted in a specially designed bridge. Bow position and force was transduced with a combination of optical sensors, including optical flow, macrobending loss under compressive strain, and with a three-axis Faraday rotator. The sensors provided sufficient resolution and dynamic range to measure cello gestures inside the MRI scanner, and no interference from the scanner was noted in the acquired signals. Further MRI compatibility testing confirmed that the interface and sensors had no meaningful effect on field homogeneity and no image artifacts were noted. The interface is currently being used in neuroscience experiments.

Details

show
hide
Language(s): eng - English
 Dates: 2015-02-192015-06-092015-06-252015-11
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1109/JSEN.2015.2449876
 Degree: -

Event

show

Legal Case

show

Project information

show hide
Project name : -
Grant ID : -
Funding program : -
Funding organization : Canada Foundation for Innovation
Project name : -
Grant ID : -
Funding program : NSERC Discovery Grant
Funding organization : atural Sciences and Engineering Research Council of Canada (NSERC)

Source 1

show
hide
Title: IEEE Sensors Journal
  Other : IEEE Sens. J.
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: New York, NY : IEEE Sensors Council
Pages: - Volume / Issue: 15 (11) Sequence Number: - Start / End Page: 6125 - 6134 Identifier: ISSN: 1530-437X
CoNE: https://pure.mpg.de/cone/journals/resource/110978984570397