Stikov, N., Boudreau, M., Levesque, I. R., Tardif, C., Barral, J. K., & Pike, G. B. (2015). On the accuracy of T1 mapping: Searching for common ground. Magnetic Resonance in Medicine, 73(2), 514-522. doi:10.1002/mrm.25135.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Stikov, Nikola1, 著者
Boudreau, Mathieu1, 著者
Levesque, Ives R.2, 著者
Tardif, Christine3, 著者           
Barral, Joëlle K.4, 著者
Pike, G. Bruce1, 著者
所属:
1McConnell Brain Imaging Centre, Montreal Neurological Institute and Hospital, McGill University, Montréal, QC, Canada, ou_persistent22              
2Department of Radiology, Stanford University, CA, USA, ou_persistent22              
3Department Neurophysics, MPI for Human Cognitive and Brain Sciences, Max Planck Society, Leipzig, DE, ou_634550              
4Department of Electrical Engineering, Stanford University, CA, USA, ou_persistent22              

内容説明

表示:
非表示:
キーワード: Relaxometry; T1 mapping; Quantitative MRI; Accuracy; Precision; Inversion recovery; Look-locker; Variable flip angle; B1 mapping
 要旨: Purpose: There are many T1 mapping methods available, each of them validated in phantoms and reporting excellent agreement with literature. However, values in literature vary greatly, with T1 in white matter ranging from 690 to 1100 ms at 3 Tesla. This brings into question the accuracy of one of the most fundamental measurements in quantitative MRI. Our goal was to explain these variations and look into ways of mitigating them. Theory and Methods: We evaluated the three most common T1 mapping methods (inversion recovery, Look-Locker, and variable flip angle) through Bloch simulations, a white matter phantom and the brains of 10 healthy subjects (single-slice). We pooled the T1 histograms of the subjects to determine whether there is a sequence-dependent bias and whether it is reproducible across subjects. Results: We found good agreement between the three methods in phantoms, but poor agreement in vivo, with the white matter T1 histogram peak in healthy subjects varying by more than 30% depending on the method used. We also found that the pooled brain histograms displayed three distinct white matter peaks, with Look-Locker consistently underestimating, and variable flip angle overestimating the inversion recovery T1 values. The Bloch simulations indicated that incomplete spoiling and inaccurate B1 mapping could account for the observed differences. Conclusion: We conclude that the three most common T1 mapping protocols produce stable T1 values in phantoms, but not in vivo. To improve the accuracy of T1 mapping, we recommend that sites perform in vivo validation of their T1 mapping method against the inversion recovery reference method, as the first step toward developing a robust calibration scheme.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2013-08-262013-12-262014-02-272015-02
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): DOI: 10.1002/mrm.25135
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Magnetic Resonance in Medicine
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: New York : Wiley-Liss
ページ: - 巻号: 73 (2) 通巻号: - 開始・終了ページ: 514 - 522 識別子(ISBN, ISSN, DOIなど): ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149