English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Correction of inter-scan motion artifacts in quantitative R1 mapping by accounting for receive coil sensitivity effects

Papp, D., Callaghan, M. F., Meyer, H., Buckley, C., & Weiskopf, N. (2016). Correction of inter-scan motion artifacts in quantitative R1 mapping by accounting for receive coil sensitivity effects. Magnetic Resonance in Medicine, 76(5), 1478-1485. doi:10.1002/mrm.26058.

Item is

Files

show Files
hide Files
:
Papp_2016.pdf (Publisher version), 522KB
Name:
Papp_2016.pdf
Description:
-
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show

Creators

show
hide
 Creators:
Papp, Daniel1, Author
Callaghan, Martina F.1, Author
Meyer, Heiko2, Author
Buckley, Craig3, Author
Weiskopf, Nikolaus1, 4, Author           
Affiliations:
1Wellcome Trust Centre for Neuroimaging, University College London, United Kingdom, ou_persistent22              
2Siemens Sector Healthcare, Erlangen, Germany, ou_persistent22              
3Siemens Healthcare, Camberley, United Kingdom, ou_persistent22              
4Department Neurophysics (Weiskopf), MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_2205649              

Content

show
hide
Free keywords: MPM; R1 mapping; VFA; Motion correction; Quantitative MRI; Receive sensitivity
 Abstract: PURPOSE:

Inter-scan motion causes differential receive field modulation between scans, leading to errors when they are combined to quantify MRI parameters. We present a robust and efficient method that accounts for inter-scan motion by removing this modulation before parameter quantification.
THEORY AND METHODS:

Five participants moved between two high-resolution structural scans acquired with different flip angles. Before each high-resolution scan, the effective relative sensitivity of the receive head coil was estimated by combining two rapid low-resolution scans acquired receiving on each of the body and head coils. All data were co-registered and sensitivity variations were removed from the high-resolution scans by division with the effective relative sensitivity. R1 maps with and without this correction were calculated and compared against reference maps unaffected by inter-scan motion.
RESULTS:

Even after coregistration, inter-scan motion significantly biased the R1 maps, leading to spurious variation in R1 in brain tissue and deviations with respect to a no-motion reference. The proposed correction scheme reduced the error to within the typical scan-rescan error observed in datasets unaffected by motion.
CONCLUSION:

Inter-scan motion negatively impacts the accuracy and precision of R1 mapping. We present a validated correction method that accounts for position-specific receive field modulation. Magn Reson Med, 2015. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.

Details

show
hide
Language(s): eng - English
 Dates: 2015-10-062015-06-252015-10-262015-11-262016-11-01
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1002/mrm.26058
PMID: 26608936
PMC: PMC5082493
Other: Epub 2015
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: New York : Wiley-Liss
Pages: - Volume / Issue: 76 (5) Sequence Number: - Start / End Page: 1478 - 1485 Identifier: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149