Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Spreading times of ion-bunches in the Cryogenic Trap forFast ion beams

Breitenfeldt, C., Froese, M. W., Blaum, K., George, S., Grieser, M., Lange, M., et al. (2015). Spreading times of ion-bunches in the Cryogenic Trap forFast ion beams. International Journal of Mass Spectrometry, 396, 1-4. doi:10.1016/j.ijms.2015.11.011.

Item is

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Breitenfeldt, Christian1, 2, Autor           
Froese, Michael Wayne1, Autor           
Blaum, Klaus1, Autor           
George, Sebastian1, Autor           
Grieser, Manfred1, Autor           
Lange, Michael1, Autor           
Menk, Sebastian1, Autor           
Repnow, Roland1, Autor           
Schwalm, Dirk1, Autor           
Schweikhard, L.2, Autor
von Hahn, Robert1, Autor           
Wolf, Andreas1, Autor           
Affiliations:
1Division Prof. Dr. Klaus Blaum, MPI for Nuclear Physics, Max Planck Society, ou_904548              
2Institut für Physik, Ernst-Moritz-Arndt Universität Greifswald, Felix-Hausdorff-Str. 6, 17487 Greifswald, Germany, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 MPINP: Speichertechnik - Abteilung Blaum
 Zusammenfassung: The decay of ion-bunches stored in the self-bunching mode of an electrostatic ion beam trap (EIBT) has been investigated as a function of the number of injected ions with the Cryogenic Trap for Fast ion beams (CTF) located at the Max Planck Institute for Nuclear Physics in Heidelberg. By use of the pickup-electrode signal the dependence of the characteristic bunch-spreading time τ, i.e. the time in which the bunch width increases by one third, on the number of injected ions is determined. For F ions with an initial bunch length of 2.7 μs the spreading times are observed to increase approximately linearly with the number of injected ions and to reach a constant value of ∼10 s for ion numbers larger than 4 × 105.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2015-12-14
 Publikationsstatus: Online veröffentlicht
 Seiten: 4
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1016/j.ijms.2015.11.011
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: International Journal of Mass Spectrometry
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Amsterdam : Elsevier
Seiten: - Band / Heft: 396 Artikelnummer: - Start- / Endseite: 1 - 4 Identifikator: ISSN: 1387-3806
CoNE: https://pure.mpg.de/cone/journals/resource/954926232412