English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Serial block-face scanning electron microscopy to reconstruct three-dimensional tissue nanostructure

Denk, W., & Horstmann, H. (2004). Serial block-face scanning electron microscopy to reconstruct three-dimensional tissue nanostructure. PLoS Biology, 2(11): e329, pp. 1900-1909. doi:10.1371/journal.pbio.0020329.

Item is

Basic

show hide
Genre: Journal Article
Alternative Title : Serial block-face scanning electron microscopy to reconstruct three-dimensional tissue nanostructure

Files

show Files
hide Files
:
PLoSBiol_2_2004_329e.pdf (Any fulltext), 3MB
 
File Permalink:
-
Name:
PLoSBiol_2_2004_329e.pdf
Description:
-
OA-Status:
Visibility:
Restricted (Max Planck Institute for Medical Research, MHMF; )
MIME-Type / Checksum:
application/pdf
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show
hide
Description:
-
OA-Status:
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Denk, Winfried1, Author           
Horstmann, Heinz1, 2, Author           
Affiliations:
1Department of Biomedical Optics, Max Planck Institute for Medical Research, Max Planck Society, ou_1497699              
2Department of Cell Physiology, Max Planck Institute for Medical Research, Max Planck Society, ou_1497701              

Content

show
hide
Free keywords: -
 Abstract: Three-dimensional (3D) structural information on many length scales is of central importance in biological research. Excellent methods exist to obtain structures of molecules at atomic, organelles at electron microscopic, and tissue at light-microscopic resolution. A gap exists, however, when 3D tissue structure needs to be reconstructed over hundreds of micrometers with a resolution sufficient to follow the thinnest cellular processes and to identify small organelles such as synaptic vesicles. Such 3D data are, however, essential to understand cellular networks that, particularly in the nervous system, need to be completely reconstructed throughout a substantial spatial volume. Here we demonstrate that datasets meeting these requirements can be obtained by automated block-face imaging combined with serial sectioning inside the chamber of a scanning electron microscope. Backscattering contrast is used to visualize the heavy-metal staining of tissue prepared using techniques that are routine for transmission electron microscopy. Low-vacuum (20–60 Pa H2O) conditions prevent charging of the uncoated block face. The resolution is sufficient to trace even the thinnest axons and to identify synapses. Stacks of several hundred sections, 50–70 nm thick, have been obtained at a lateral position jitter of typically under 10 nm. This opens the possibility of automatically obtaining the electron-microscope-level 3D datasets needed to completely reconstruct the connectivity of neuronal circuits.

Details

show
hide
Language(s): eng - English
 Dates: 2004-05-232004-07-292004-10-192004-11-01
 Publication Status: Issued
 Pages: 10
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: PLoS Biology
  Other : PLoS Biol.
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Public Library of Science
Pages: - Volume / Issue: 2 (11) Sequence Number: e329 Start / End Page: 1900 - 1909 Identifier: ISSN: 1544-9173
CoNE: https://pure.mpg.de/cone/journals/resource/111056649444170