English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Sensitivity enhancement in pulse EPR distance measurements

Jeschke, G., Bender, A., Paulsen, H., Zimmermann, H., & Godt, A. (2004). Sensitivity enhancement in pulse EPR distance measurements. Journal of Magnetic Resonance, 169(1), 1-12. doi:10.1016/j.jmr.2004.03.024.

Item is

Basic

show hide
Genre: Journal Article
Alternative Title : Sensitivity enhancement in pulse EPR distance measurements

Files

show Files
hide Files
:
JMagnReson_169_2004_1.pdf (Any fulltext), 378KB
 
File Permalink:
-
Name:
JMagnReson_169_2004_1.pdf
Description:
-
OA-Status:
Visibility:
Restricted (Max Planck Institute for Medical Research, MHMF; )
MIME-Type / Checksum:
application/pdf
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Creators

show
hide
 Creators:
Jeschke, Gunnar, Author
Bender, A., Author
Paulsen, H., Author
Zimmermann, Herbert1, Author           
Godt, Adelheid, Author
Affiliations:
1Emeritus Group Biophysics, Max Planck Institute for Medical Research, Max Planck Society, ou_1497712              

Content

show
hide
Free keywords: EPR; ELDOR; Spin labeling; Protein structure; Pair correlation function
 Abstract: Established pulse EPR approaches to the measurement of small dipole-dipole couplings between electron spins rely on constant-time echo experiments to separate relaxational contributions from dipolar time evolution. This requires a compromise between sensitivity and resolution to be made prior to the measurement, so that optimum data are only obtained if the magnitude of the dipole-dipole coupling is known beforehand to a good approximation. Moreover, the whole dipolar evolution function is measured with relatively low sensitivity. These problems are overcome by a variable-time experiment that achieves suppression of the relaxation contribution by reference deconvolution. Theoretical and experimental results show that this approach leads to significant sensitivity improvements for typical systems and experimental conditions. Further sensitivity improvements or, equivalently, an extension of the accessible distance range can be obtained by matrix deuteration or digital long-pass filtering of the time-domain data. Advantages and limitations of the new variable-time experiment are discussed by comparing it to the established analogous constant-time experiment for measurements of end-to-end distances of 5 and 7.5 nm on rod-like shape-persistent biradicals and for the measurement of a broadly distributed transmembrane distance in a doubly spin-labeled mutant of plant light harvesting complex II.

Details

show
hide
Language(s): eng - English
 Dates: 2004-01-202004-03-072004-04-222004-07-01
 Publication Status: Issued
 Pages: 12
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Journal of Magnetic Resonance
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: San Diego [etc.] : Academic Press
Pages: - Volume / Issue: 169 (1) Sequence Number: - Start / End Page: 1 - 12 Identifier: ISSN: 1090-7807
CoNE: https://pure.mpg.de/cone/journals/resource/954922651175_1