English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Short duration water suppresion using optimised flip angles (SODA) at ultra high fields

Giapitzakis, I., Nassirpour, S., & Henning, A. (2015). Short duration water suppresion using optimised flip angles (SODA) at ultra high fields. Magnetic Resonance Materials in Physics, Biology and Medicine, 28(Supplement 1), S401-S402.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Giapitzakis, IA1, Author           
Nassirpour, S2, Author           
Henning, A1, Author           
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              

Content

show
hide
Free keywords: -
 Abstract: Purpose/Introduction: Proton magnetic resonance spectroscopy (MRS) enables the detection of several metabolites within the human body. The concentration of water is av thousand times higher than those of the metabolites. As a consequence, it introduces baseline distortions, eddy current and gradient modulation artifacts in the final spectrum [1–2]. Several techniques have been developed trying to suppress the water peak using special water suppression (WS) methods [3–4] etc. At low magnetic fields (i.e.\3 T) the performance of the aforementioned WS techniques can be quite good. However, at higher magnetic fields this is a difficult task due to B1 + inhomogeneity. A solution to this problem is the development of VAPOR [5]. This method enables very good WS against B1 + ingomogeneity at the expense of time (*700 ms). This duration can prolong significantly the examination time, especially in case of time consuming sequences (e.g. multi slice MRSI). For this reason, the aim of this study was the development of a short duration water suppression using optimised flip angles (SODA) at 9.4 T. Subjects and Methods: An algorithm was developed trying to minimize the residual longitudinal magnetization for different number of CHESS [4] pulses, T1 relaxation times, B1 + inhomogeneity and time delays (Fig. 1). After the determination of the desired flip angles and time delays, an algorithm was written in order to find the best combination of gradient amplitudes for the suppression of the unwanted coherence pathways (Fig. 2; after n pulses, 3n coherence pathways are produced). Afterwards, the final WS sequence was incorporated with a STEAM technique and tested on a phantom and a healthy volunteer. All the experiments were carried out using a 4 channel transceiver array coil connected to a whole body 9.4 Tesla SIEMENS scanner. Results: The phantom results demonstrated a suppression of 99.7 of the initial water peak (suppression factor = 449; Fig. 3). In addition, in vivo results showed that SODA scheme allows sufficient WS giving a suppression factor[1300. Discussion/Conclusion: In this study we demonstrated a short duration WS scheme using optimized flip angles (SODA) and gradients showing preliminary results of this study. This method has a lot of room for improvements such as the introduction of phase cycling during SODA and the replacement of the Gaussian pulses with pulses with better profiles.

Details

show
hide
Language(s):
 Dates: 2015-10
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1007/s10334-015-0489-0
BibTex Citekey: GiapitzakisNH2015
 Degree: -

Event

show
hide
Title: 32nd Annual Scientific Meeting ESMRMB 2015
Place of Event: Edinburgh, UK
Start-/End Date: -

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance Materials in Physics, Biology and Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 28 (Supplement 1) Sequence Number: - Start / End Page: S401 - S402 Identifier: -