English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  T1 relaxometry and tissue segmentation of the human brain at 9.4T and 3T using MP2RAGE

Hagberg, G., Bause, J., Ethofer, T., Dresler, T., Herbert, C., Pohmann, R., et al. (2015). T1 relaxometry and tissue segmentation of the human brain at 9.4T and 3T using MP2RAGE. Magnetic Resonance Materials in Physics, Biology and Medicine, 28(Supplement 1), S234-S235.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:
Not specified

Creators

show
hide
 Creators:
Hagberg, GE1, 2, Author           
Bause, J2, Author           
Ethofer, T, Author                 
Dresler, T, Author
Herbert, C, Author
Pohmann, R2, 3, Author           
Shajan, G2, Author           
Fallgatter, A, Author
Scheffler, K2, Author           
Affiliations:
1Department Physiology of Cognitive Processes, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497798              
2Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
3Dept. Empirical Inference, Max Planck Institute for Intelligent Systems, Max Planck Society, ou_1497647              

Content

show
hide
Free keywords: -
 Abstract: Purpose/Introduction: Accurate and precise determination of T1 values is of central importance in clinical studies and for tissue segmentation based on the myeloarchitecture that transcends T1 [1]. The MP2RAGE sequence is attractive for use at high field since the resulting T1 values are valid across a large range of transmit field inhomogeneities [2]. Here we investigate the use of this technique for whole brain segmentation and T1 relaxometry at 9.4T and compared
the results to data obtained 3T.
Subjects and Methods: The study was ERB approved and MRI was
performed in healthy volunteers (21–56y N = 11) at 9.4T using a 16ch transmit/31ch receive array [3], at 3T a 2ch body transmit coil 32ch receive array. At 9.4T, B1 + mapping with the Actual Flip Angle method [4] and MP2RAGE (TI1/TI2 = 900/3500 ms; FA = 4/6; TR_GRE = 6 ms; TR = 8894 ms, 0.8 mm isotropic voxel size) were performed. The sequence parameters used at 3T were slightly different (TI1/TI2 = 700/2500 ms; FA = 4/5; TR_GRE = 7.7 ms; TR = 5000 ms, 0.8 mm isotropic voxel size). Standard m ethods for automatic brain segmentation in SPM12 based on T1 weighted images or flip angle corrected T1 maps and the IBA
SPM tool were employed to define brain areas for analysis.
Results: The actual flip angle observed in vivo deviated by 40 and more from the nominal angle so the intrinsic bias correction of the MP2RAGE method failed in brain regions with the highest B1 field. As a consequence, the outcome of brain segmentation deteriorated, leading to mis-classifiation of several grey matter voxels, especially
those located in sub cortical areas. Flip angle correction of the MP2RAGE maps acquired at 9.4T substantially improved segmentation and yielded grey matter classification highly similar to the one at 3T (Fig. 1). T1 values extracted in IBA segmented areas showed high consistency across subjects at both field strengths with standard deviations below 3.5 , but showed a greater dynamic range at 9.4T.
Discussion/Conclusion: The intrinsic bias correction of MP2RAGE does not suffice to achieve reliable T1 quantification at UHF. Provided transmit field correction is performed, T1 maps with high intersubject consistency is obtained at 9.4T, holding promise for investigation of local myeloarchitectonics in neuroscientific and clinical studies.

Details

show
hide
Language(s):
 Dates: 2015-10
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1007/s10334-015-0488-1
BibTex Citekey: HagbergBEDHPSFS2015
 Degree: -

Event

show
hide
Title: 32nd Annual Scientific Meeting ESMRMB 2015
Place of Event: Edinburgh, UK
Start-/End Date: -

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance Materials in Physics, Biology and Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Amsterdam : No longer published by Elsevier
Pages: - Volume / Issue: 28 (Supplement 1) Sequence Number: - Start / End Page: S234 - S235 Identifier: ISSN: 0968-5243
CoNE: https://pure.mpg.de/cone/journals/resource/954926245532