Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  T1 relaxometry and tissue segmentation of the human brain at 9.4T and 3T using MP2RAGE

Hagberg, G., Bause, J., Ethofer, T., Dresler, T., Herbert, C., Pohmann, R., et al. (2015). T1 relaxometry and tissue segmentation of the human brain at 9.4T and 3T using MP2RAGE. Magnetic Resonance Materials in Physics, Biology and Medicine, 28(Supplement 1), S234-S235.

Item is

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:
Keine Angabe

Urheber

einblenden:
ausblenden:
 Urheber:
Hagberg, GE1, 2, Autor           
Bause, J2, Autor           
Ethofer, T, Autor
Dresler, T, Autor
Herbert, C, Autor
Pohmann, R2, 3, Autor           
Shajan, G2, Autor           
Fallgatter, A, Autor
Scheffler, K2, Autor           
Affiliations:
1Department Physiology of Cognitive Processes, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497798              
2Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
3Dept. Empirical Inference, Max Planck Institute for Intelligent Systems, Max Planck Society, ou_1497647              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Purpose/Introduction: Accurate and precise determination of T1 values is of central importance in clinical studies and for tissue segmentation based on the myeloarchitecture that transcends T1 [1]. The MP2RAGE sequence is attractive for use at high field since the resulting T1 values are valid across a large range of transmit field inhomogeneities [2]. Here we investigate the use of this technique for whole brain segmentation and T1 relaxometry at 9.4T and compared the results to data obtained 3T. Subjects and Methods: The study was ERB approved and MRI was performed in healthy volunteers (21–56y N = 11) at 9.4T using a 16ch transmit/31ch receive array [3], at 3T a 2ch body transmit coil 32ch receive array. At 9.4T, B1 + mapping with the Actual Flip Angle method [4] and MP2RAGE (TI1/TI2 = 900/3500 ms; FA = 4/6; TR_GRE = 6 ms; TR = 8894 ms, 0.8 mm isotropic voxel size) were performed. The sequence parameters used at 3T were slightly different (TI1/TI2 = 700/2500 ms; FA = 4/5; TR_GRE = 7.7 ms; TR = 5000 ms, 0.8 mm isotropic voxel size). Standard m ethods for automatic brain segmentation in SPM12 based on T1 weighted images or flip angle corrected T1 maps and the IBA SPM tool were employed to define brain areas for analysis. Results: The actual flip angle observed in vivo deviated by 40 and more from the nominal angle so the intrinsic bias correction of the MP2RAGE method failed in brain regions with the highest B1 field. As a consequence, the outcome of brain segmentation deteriorated, leading to mis-classifiation of several grey matter voxels, especially those located in sub cortical areas. Flip angle correction of the MP2RAGE maps acquired at 9.4T substantially improved segmentation and yielded grey matter classification highly similar to the one at 3T (Fig. 1). T1 values extracted in IBA segmented areas showed high consistency across subjects at both field strengths with standard deviations below 3.5 , but showed a greater dynamic range at 9.4T. Discussion/Conclusion: The intrinsic bias correction of MP2RAGE does not suffice to achieve reliable T1 quantification at UHF. Provided transmit field correction is performed, T1 maps with high intersubject consistency is obtained at 9.4T, holding promise for investigation of local myeloarchitectonics in neuroscientific and clinical studies.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2015-10
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1007/s10334-015-0488-1
BibTex Citekey: HagbergBEDHPSFS2015
 Art des Abschluß: -

Veranstaltung

einblenden:
ausblenden:
Titel: 32nd Annual Scientific Meeting ESMRMB 2015
Veranstaltungsort: Edinburgh, UK
Start-/Enddatum: -

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance Materials in Physics, Biology and Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 28 (Supplement 1) Artikelnummer: - Start- / Endseite: S234 - S235 Identifikator: -