Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Expected Homogeneity Gain and Hardware Requirements for Slice-Wise 3rd Order Dynamic Shim Updating for fMRI

Fillmer, A., & Henning, A. (2015). Expected Homogeneity Gain and Hardware Requirements for Slice-Wise 3rd Order Dynamic Shim Updating for fMRI. Poster presented at 23rd Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2015), Toronto, Canada.

Item is

Externe Referenzen

ausblenden:
externe Referenz:
http://www.ismrm.org/15/program_files/MonEPS04.htm (Verlagsversion)
Beschreibung:
-
OA-Status:

Urheber

ausblenden:
 Urheber:
Fillmer, A, Autor
Henning, A1, 2, Autor           
Affiliations:
1Research Group MR Spectroscopy and Ultra-High Field Methodology, Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_2528692              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

Inhalt

ausblenden:
Schlagwörter: -
 Zusammenfassung: EPI allows for very fast acquisition, and is the “work horse” of conventional fMRI. To exploit the full advantage of applying ultra-high fields to fMRI, sophisticated B0 shim strategies are required. An auspicious approach for improving B0 homogeneity is DSU. As eddy-currents arise from fast switching of shim currents a careful pre-emphasis calibration is necessary. The application of pre-emphasis requires the limitation of the shim fields, which limits the homogeneity gain expected from DSU. This work compares the expected homogeneity gain from a global and a slice-wise DSU shim approach and investigates the hardware requirements for optimal slice-wise dynamic shimming.

Details

ausblenden:
Sprache(n):
 Datum: 2015-06
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: BibTex Citekey: FillmerH2015_3
 Art des Abschluß: -

Veranstaltung

ausblenden:
Titel: 23rd Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2015)
Veranstaltungsort: Toronto, Canada
Start-/Enddatum: 2015-05-30 - 2015-06-05

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

ausblenden:
Titel: 23rd Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2015)
Genre der Quelle: Konferenzband
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: - Artikelnummer: 3211 Start- / Endseite: - Identifikator: -