Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Towards routine application of dynamic parallel transmission for whole-brain imaging at 9.4 Tesla

Hoffmann, J., Shajan, G., Mirkes, C., Shao, T., Henning, A., Pohmann, R., et al. (2015). Towards routine application of dynamic parallel transmission for whole-brain imaging at 9.4 Tesla. Poster presented at 23rd Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2015), Toronto, Canada.

Item is

Externe Referenzen

einblenden:
ausblenden:
externe Referenz:
http://www.ismrm.org/15/program_files/MonEPS04.htm (Verlagsversion)
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Hoffmann, J1, 2, Autor           
Shajan, G1, 2, Autor           
Mirkes, C1, 2, Autor           
Shao, T1, 2, Autor           
Henning, A2, 3, Autor           
Pohmann, R1, 2, Autor           
Scheffler, K1, 2, Autor           
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              
3Research Group MR Spectroscopy and Ultra-High Field Methodology, Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_2528692              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: The requirements for implementing a multi-purpose, pTx-enabled RF setup for whole-brain imaging at 9.4 Tesla are high. They include transmit arrays with sensitivities distributed in all dimensions, receive hardware for high-SNR parallel signal reception, numerical simulations for compliance with SAR limits as well as rapid, volumetric calibration scans. In this work, we report our progress in achieving these objectives. A 16-channel dual-row Tx / 31-channel Rx-array combination was interfaced to an 8-channel pTx system. SAR was evaluated numerically, rapid calibration scans were acquired using a 3D DREAM sequence and superior excitation quality using Spokes pulses is demonstrated in vivo.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2015-06
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: BibTex Citekey: HoffmannSMSHPS2015
 Art des Abschluß: -

Veranstaltung

einblenden:
ausblenden:
Titel: 23rd Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2015)
Veranstaltungsort: Toronto, Canada
Start-/Enddatum: 2015-05-30 - 2015-06-05

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: 23rd Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2015)
Genre der Quelle: Konferenzband
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: - Artikelnummer: 3201 Start- / Endseite: - Identifikator: -