日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  SNR and Line Shape Improvement in Overdiscrete MRSI Reconstruction

Kirchner, T., Fillmer, A., Pruessmann, K., & Henning, A. (2015). SNR and Line Shape Improvement in Overdiscrete MRSI Reconstruction. Poster presented at 10th Annual Meeting of the European Society for Molecular Imaging (EMIM 2015), Tübingen, Germany.

Item is

基本情報

表示: 非表示:
資料種別: ポスター

ファイル

表示: ファイル

関連URL

表示:
非表示:
説明:
-
OA-Status:

作成者

表示:
非表示:
 作成者:
Kirchner, T, 著者
Fillmer, A, 著者
Pruessmann, KP, 著者
Henning, A1, 2, 著者           
所属:
1Research Group MR Spectroscopy and Ultra-High Field Methodology, Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_2528692              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

内容説明

表示:
非表示:
キーワード: -
 要旨: Introduction Critical usability assessment criteria for Magnetic Resonance Spectroscopic Imaging (MRSI) include spectral resolution and signal-to-noise ratio (SNR). In practice, scan time limitations dictate a spatial resolution which is rather coarse compared to pure imaging. This leads to voxel bleeding artefacts reflected in imperfections of the Spatial Response Function (SRF). To reduce them, target-driven overdiscrete reconstruction has been investigated and found to lead to favourable trade-offs for MRSI [1, 2]. This approach furthermore allows to correct for inhomogeneities of the main magnetic field (B0) in a quasi-continuous manner, yielding SNR increase [3]. In this work, the effect on SNR and spectral resolution is investigated in detail and a technical explanation is given. Methods An intermediate spectroscopic image (iSI) with a higher-than-nominal spatial resolution but low SNR is created after application of the first part of the reconstruction operator [3]. The second part then amounts to application of the SRF target function to the iSI, i.e. a spatial averaging. Prior to that, the spectra in the iSI are frequency-aligned according to a separately acquired B0 map on a subvoxel level. The example data presented are a 1H MRSI acquired at 7T with a nominal 20x16 resolution using the FIDLOVS [4] sequence with and without water suppression. Results Fig. 1B contains a subset of in vivo example spectra after eddy current [5] and phase correction from the indicated voxel positions (Fig. 1A, underlying B0 distribution included). Mean SNR improvement by a factor of 4.2 by B0 correction on the intermediate spectroscopic image is obvious. The effect is due to the destruction of previously existing noise correlation between neighboring subvoxels (Fig. 2A). The distribution of SNR of the NAA peak at 2.0 ppm and the fit results of a Voigt line fit to the water peak in the non-water suppressed scan are shown in Fig. 2B, indicating narrower line shapes and hence improved spectral resolution. Conclusions When using target-driven overdiscrete reconstruction, major SNR and line width improvement may be achieved simultaneously by performing B0 correction at the level of the iSI. The additional effort of acquiring the necessary B0 map is usually small compared to the MRSI measurement.

資料詳細

表示:
非表示:
言語:
 日付: 2015-03-19
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): BibTex参照ID: KirchnerFPH2015_2
 学位: -

関連イベント

表示:
非表示:
イベント名: 10th Annual Meeting of the European Society for Molecular Imaging (EMIM 2015)
開催地: Tübingen, Germany
開始日・終了日: -

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: 10th Annual Meeting of the European Society for Molecular Imaging (EMIM 2015)
種別: 会議論文集
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: - 通巻号: 376 開始・終了ページ: - 識別子(ISBN, ISSN, DOIなど): -