Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Role of implant configurations supporting three-unit fixed partial denture on mandibular bone response : biological-data-based finite element study

Yoda, N., Liao, Z., Chen, J., Sasaki, K., Swain, M., & Li, Q. (2016). Role of implant configurations supporting three-unit fixed partial denture on mandibular bone response: biological-data-based finite element study. Journal of Oral Rehabilitation, 43(9), 692-701. doi:10.1111/joor.12411.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
2298715.pdf (Verlagsversion), 935KB
 
Datei-Permalink:
-
Name:
2298715.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Eingeschränkt (Max Planck Institute of Colloids and Interfaces, MTKG; )
MIME-Typ / Prüfsumme:
application/pdf
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-
:
2298715_supp.tif (Ergänzendes Material), 3MB
Name:
2298715_supp.tif
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
image/tiff / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Yoda, N., Autor
Liao, Z., Autor
Chen, J.1, Autor           
Sasaki, K., Autor
Swain, M., Autor
Li, Q., Autor
Affiliations:
1Richard Weinkamer, Biomaterialien, Max Planck Institute of Colloids and Interfaces, Max Planck Society, ou_1863295              

Inhalt

einblenden:
ausblenden:
Schlagwörter: dental implant, transducers, fixed partial denture, bite force, finite element analysis, biomechanics
 Zusammenfassung: Implant-supported fixed partial denture with cantilever extension can transfer the excessive load to the bone around implants and stress/strain concentration potentially leading to bone resorption. This study investigated the effects of implant configurations supporting three-unit fixed partial denture (FPD) on the stress and strain distribution in the peri-implant bone by combining clinically measured time-dependent loading data and finite element (FE) analysis. A 3-dimensional mandibular model was constructed based on computed tomography (CT) images. Four different configurations of implants supporting 3-unit FPDs, namely three implant-supported FPD, conventional three-unit bridge FPD, distal cantilever FPD and mesial cantilever FPD, were modelled. The FPDs were virtually inserted to the molar area in the mandibular FE models. The FPDs were loaded according to time-dependent in vivo-measured 3-dimensional loading data during chewing. The von Mises stress (VMS) and equivalent strain (EQS) in peri-implant bone regions were evaluated as mechanical stimuli. During the chewing cycles, the regions near implant necks and bottom apexes experienced high VMS and EQS than the middle regions in all implant-supported FPD configurations. Higher VMS and EQS values were also observed at the implant neck region adjacent to the cantilever extension in the cantilevered configurations. The patient-specific dynamic loading data and CT-based reconstruction of full 3D mandibular allowed us to model the biomechanical responses more realistically. The results provided data for clinical assessment of implant configuration to improve longevity and reliability of the implant-supported FPD restoration.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2016-05-252016
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1111/joor.12411
BibTex Citekey: JOOR:JOOR12411
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Journal of Oral Rehabilitation
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Oxford, UK : Wiley Blackwell
Seiten: - Band / Heft: 43 (9) Artikelnummer: - Start- / Endseite: 692 - 701 Identifikator: ISSN: 1365-2842