English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  A semi-simulated EEG/EOG dataset for the comparison of EOG artifact rejection techniques

Klados, M., & Bamidis, P. D. (2016). A semi-simulated EEG/EOG dataset for the comparison of EOG artifact rejection techniques. Data in Brief, 8, 1004-1006. doi:10.1016/j.dib.2016.06.032.

Item is

Files

show Files
hide Files
:
Klados_Bamidis_2016.pdf (Publisher version), 170KB
Name:
Klados_Bamidis_2016.pdf
Description:
-
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show
hide
Locator:
Link (Any fulltext)
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Klados, Manousos1, 2, Author           
Bamidis, Panagiotis D.2, Author
Affiliations:
1Max Planck Research Group Neuroanatomy and Connectivity, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_1356546              
2Laboratory of Medical Physics, School of Medicine, Faculty of Health Sciences, Aristotle University of Thessaloniki, Greece, ou_persistent22              

Content

show
hide
Free keywords: EEG; EOG; Artifact Rejection
 Abstract: Artifact rejection techniques are used to recover the brain signals underlying artifactual electroencephalographic (EEG) segments. Although over the last few years many different artifact rejection techniques have been proposed (http://dx.doi.org/10.1109/JSEN.2011.2115236[1], http://dx.doi.org/10.1016/j.clinph.2006.09.003[2], http://dx.doi.org/10.3390/e16126553[3]), none has been established as a gold standard so far, because assessing their performance is difficult and subjective (http://dx.doi.org/10.1109/ITAB.2009.5394295[4], http://dx.doi.org/10.1016/j.bspc.2011.02.001[5], http://dx.doi.org/10.1007/978-3-540-89208-3_300. [6]). This limitation is mainly based on the fact that the underlying artifact-free brain signal is unknown, so there is no objective way to measure how close the retrieved signal is to the real one. This article solves the aforementioned problem by presenting a semi-simulated EEG dataset, where artifact-free EEG signals are manually contaminated with ocular artifacts, using a realistic head model. The significant part of this dataset is that it contains the pre-contamination EEG signals, so the brain signals underlying the EOG artifacts are known and thus the performance of every artifact rejection technique can be objectively assessed.

Details

show
hide
Language(s): eng - English
 Dates: 2016-06-122016-01-222016-06-212016-06-29
 Publication Status: Published online
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1016/j.dib.2016.06.032
BibTex Citekey: Klados2016
PMID: 27508255
PMC: PMC4969208
Other: eCollection 2016
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Data in Brief
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Dordrecht : Elsevier
Pages: - Volume / Issue: 8 Sequence Number: - Start / End Page: 1004 - 1006 Identifier: ISSN: 2352-3409
CoNE: https://pure.mpg.de/cone/journals/resource/2352-3409