  Cryoflow: Cryofocusing nanomole amounts of CO2, N2, and SO2 from an elemental analyzer for stable isotopic analysis

Fry, B., Ganitt, R., Tholke, K., Neill, C., Michener, R. H., Mersch, F. J., et al. (1996). Cryoflow: Cryofocusing nanomole amounts of CO2, N2, and SO2 from an elemental analyzer for stable isotopic analysis. Rapid Communications in Mass Spectrometry, 10(8), 953-958. doi:10.1002/(SICI)1097-0231(19960610)10:8<953:AID-RCM534>3.0.CO;2-0.

Item is

Files

show Files
hide Files
:
BEX555.pdf (Publisher version), 499KB
 
File Permalink:
-
Name:
BEX555.pdf
Description:
-
OA-Status:
Visibility:
Restricted (Max Planck Institute for Biogeochemistry, MJBK; )
MIME-Type / Checksum:
application/pdf
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show

Creators

show
hide
 Creators:
Fry, Brian, Author
Ganitt, Robert, Author
Tholke, Kris, Author
Neill, Christopher, Author
Michener, Robert H., Author
Mersch, F. J., Author
Brand, Willi A.1, Author           
Affiliations:
1External Organizations, ou_persistent22              

Content

show
hide
Free keywords: -
 Abstract: A manual "cryoflow' system is described for measuring C, N and S isotopic compositions of small gas samples in the 10–1000 nmol range. Using a continuous flow system with helium as the carrier gas, sample gases are injected or produced via combustion in an elemental analyzer, purified, separated and collected in separate traps with cryogens, then degassed into a slowly flowing helium stream (1–4 mL/min) for measurement with an isotope rato mass spectrometer. Blanks associated with combustion of organics in an elemental analyzer were 5–20 nmol for N and C, and not detectable for S, so that samples of >50 nmol C, N or S could be routinely analyzed with a precision of better than 0.3‰ after blank correction. In some cases, slow degassing of sample gases from traps over several minutes gave broad, low-amplitude peaks that yielded high-precision measurements (e.g., <0.05‰ δ13C differences between replicates). Work with this manual prototype showed that it is possible to routinely obtain high precision isotope measurements for C, N and S isotopes from the same small sample.

Details

show
hide
Language(s):
 Dates: 1996-04-101996
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Rapid Communications in Mass Spectrometry
  Other : Rapid Commun. Mass Spectrom.
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: New York, NY : John Wiley & Sons
Pages: - Volume / Issue: 10 (8) Sequence Number: - Start / End Page: 953 - 958 Identifier: ISSN: 0951-4198
CoNE: https://pure.mpg.de/cone/journals/resource/954925574961