Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Simulation of multi-stage nonlinear bone remodeling induced by fixed partial dentures of different configurations : a comparative clinical and numerical study

Liao, Z., Yoda, N., Chen, J., Zheng, K., Sasaki, K., Swain, M. V., et al. (2017). Simulation of multi-stage nonlinear bone remodeling induced by fixed partial dentures of different configurations: a comparative clinical and numerical study. Biomechanics and Modeling in Mechanobiology, 16(2), 411-423. doi:10.1007/s10237-016-0826-x.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
2346523.pdf (Verlagsversion), 8MB
 
Datei-Permalink:
-
Name:
2346523.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Eingeschränkt (Max Planck Institute of Colloids and Interfaces, MTKG; )
MIME-Typ / Prüfsumme:
application/pdf
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Liao, Zhipeng, Autor
Yoda, Nobuhiro, Autor
Chen, Junning1, Autor           
Zheng, Keke, Autor
Sasaki, Keiichi, Autor
Swain, Michael V., Autor
Li, Qing, Autor
Affiliations:
1Richard Weinkamer, Biomaterialien, Max Planck Institute of Colloids and Interfaces, Max Planck Society, ou_1863295              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: This paper aimed to develop a clinically validated bone remodeling algorithm by integrating bone’s dynamic properties in a multi-stage fashion based on a four-year clinical follow-up of implant treatment. The configurational effects of fixed partial dentures (FPDs) were explored using a multi-stage remodeling rule. Three-dimensional real-time occlusal loads during maximum voluntary clenching were measured with a piezoelectric force transducer and were incorporated into a computerized tomography-based finite element mandibular model. Virtual X-ray images were generated based on simulation and statistically correlated with clinical data using linear regressions. The strain energy density-driven remodeling parameters were regulated over the time frame considered. A linear single-stage bone remodeling algorithm, with a single set of constant remodeling parameters, was found to poorly fit with clinical data through linear regression (low R2 and R), whereas a time-dependent multi-stage algorithm better simulated the remodeling process (high R2 and R) against the clinical results. The three-implant-supported and distally cantilevered FPDs presented noticeable and continuous bone apposition, mainly adjacent to the cervical and apical regions. The bridged and mesially cantilevered FPDs showed bone resorption or no visible bone formation in some areas. Time-dependent variation of bone remodeling parameters is recommended to better correlate remodeling simulation with clinical follow-up. The position of FPD pontics plays a critical role in mechanobiological functionality and bone remodeling. Caution should be exercised when selecting the cantilever FPD due to the risk of overloading bone resorption.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2016-09-152017
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1007/s10237-016-0826-x
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Biomechanics and Modeling in Mechanobiology
  Andere : Biomech. Model. Mechanobiol.
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Berlin : Springer
Seiten: - Band / Heft: 16 (2) Artikelnummer: - Start- / Endseite: 411 - 423 Identifikator: ISSN: 1617-7959