Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  First observation of SASE radiation using the compact wide-spectral-range XUV spectrometer at FLASH2.

Tanikawa, T., Hage, A., Kuhlmann, M., Gonschior, J., Grunewald, S., Plonjes, E., et al. (2016). First observation of SASE radiation using the compact wide-spectral-range XUV spectrometer at FLASH2. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 830, 170-175. doi:10.1016/j.nima.2016.05.088.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
2350288.pdf (Verlagsversion), 5MB
 
Datei-Permalink:
-
Name:
2350288.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Eingeschränkt (Embargo bis 2018-05-24) (UNKNOWN id 303; )
MIME-Typ / Prüfsumme:
application/pdf
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Tanikawa, T., Autor
Hage, A., Autor
Kuhlmann, M., Autor
Gonschior, J., Autor
Grunewald, S., Autor
Plonjes, E., Autor
Düsterer, S., Autor
Brenner, G., Autor
Dziarzhytski, S., Autor
Braune, M., Autor
Brachmanski, M., Autor
Yin, Z.1, Autor           
Siewert, F., Autor
Dzelzainis, T., Autor
Dromey, B., Autor
Prandolini, M. J., Autor
Tavella, F., Autor
Zepf, M., Autor
Faatz, B., Autor
Affiliations:
1Research Group of Structural Dynamics of (Bio)Chemical Systems, MPI for biophysical chemistry, Max Planck Society, 15915              

Inhalt

einblenden:
ausblenden:
Schlagwörter: FEL; SASE; XUV; Spectrometer; AFM
 Zusammenfassung: The Free-electron LASer in Hamburg (FLASH) has been extended with a new undulator line FLASH2 in 2014. A compact grazing-incident wide-spectral-range spectrometer based on spherical-variable-line spacing (SVLS) gratings in the extreme ultraviolet (XUV) region was constructed to optimize and characterize the free-electron laser (FEL) performance at FLASH2. The spectrometer is equipped with three different concave SVLS gratings covering a spectral range from 1 to 62 nm to analyze the spectral characteristics of the XUV radiation. Wavelength calibration and evaluation of the spectral resolution were performed at the plane grating monochromator beamline PG2 at FLASH1 before the installation at FLASH2, and compared with analytical simulations. The first light using self-amplified spontaneous emission from FLASH2 was observed by the spectrometer during a simultaneous operation of both undulator lines-FLASH1 and FLASH2. In addition, the spectral resolution of the spectrometer was evaluated by comparing the measured spectrum from FLASH2 with FEL simulations.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2016-05-242016-09-11
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1016/j.nima.2016.05.088
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 830 Artikelnummer: - Start- / Endseite: 170 - 175 Identifikator: -