English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Image denoising for real-time MRI.

Klosowski, J., & Frahm, J. (2017). Image denoising for real-time MRI. Magnetic Resonance in Medicine, 77(3), 1340-1352. doi:10.1002/mrm.26205.

Item is

Files

show Files
hide Files
:
2351068.pdf (Publisher version), 3MB
 
File Permalink:
-
Name:
2351068.pdf
Description:
-
OA-Status:
Visibility:
Restricted (UNKNOWN id 303; )
MIME-Type / Checksum:
application/pdf
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-
:
2351068_Suppl.docx (Supplementary material), 2MB
Name:
2351068_Suppl.docx
Description:
-
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/vnd.openxmlformats-officedocument.wordprocessingml.document / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show

Creators

show
hide
 Creators:
Klosowski, J.1, Author           
Frahm, J.1, Author           
Affiliations:
1Biomedical NMR Research GmbH, MPI for biophysical chemistry, Max Planck Society, ou_578634              

Content

show
hide
Free keywords: Real-time MRI; Patch-based denoising; Nonlocal means; Nonlinear inversion
 Abstract: Purpose To develop an image noise filter suitable for MRI in real time (acquisition and display), which preserves small isolated details and efficiently removes background noise without introducing blur, smearing, or patch artifacts. Theory and Methods The proposed method extends the nonlocal means algorithm to adapt the influence of the original pixel value according to a simple measure for patch regularity. Detail preservation is improved by a compactly supported weighting kernel that closely approximates the commonly used exponential weight, while an oracle step ensures efficient background noise removal. Denoising experiments were conducted on real-time images of healthy subjects reconstructed by regularized nonlinear inversion from radial acquisitions with pronounced undersampling. Results The filter leads to a signal-to-noise ratio (SNR) improvement of at least 60% without noticeable artifacts or loss of detail. The method visually compares to more complex state-of-the-art filters as the block-matching three-dimensional filter and in certain cases better matches the underlying noise model. Acceleration of the computation to more than 100 complex frames per second using graphics processing units is straightforward. Conclusion The sensitivity of nonlocal means to small details can be significantly increased by the simple strategies presented here, which allows partial restoration of SNR in iteratively reconstructed images without introducing a noticeable time delay or image artifacts.

Details

show
hide
Language(s): eng - English
 Dates: 2016-04-152017-03
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1002/mrm.26205
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 77 (3) Sequence Number: - Start / End Page: 1340 - 1352 Identifier: -