English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Consistencies of the neutron detection effciency in the Double Chooz reactor neutrino detectors

Almazan Molina, H. (2016). Consistencies of the neutron detection effciency in the Double Chooz reactor neutrino detectors. Master Thesis, Ruprecht-Karls-Universität, Heidelberg.

Item is

Files

show Files
hide Files
:
MasterThesis-HAlmazan.pdf (Any fulltext), 8MB
Name:
MasterThesis-HAlmazan.pdf
Description:
-
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show

Creators

show
hide
 Creators:
Almazan Molina, Helena1, Author           
Affiliations:
1Division Prof. Dr. Manfred Lindner, MPI for Nuclear Physics, Max Planck Society, ou_904549              

Content

show
hide
Free keywords: -
 Abstract: The Double Chooz experiment, analysing the reactor antineutrinos signal from the nuclear power plant in Chooz (France), aims for a precision measurement of the neutrino mixing angle θ13 with the new data collected at the near and far detectors. An accurate and precisely known detection efficiency of the electron antineutrino interaction ve + p -> e+ + n, called inverse beta decay (IBD), is required in order to reach that goal. The correlated signal caused by the IBD interaction requires a good estimation of the neutron detection e_ciency, dominant uncertainty in the θ13 estimation. Among other calibration methods, the deployment of the 252Cf radioactive source along the detectors' inner volumes is used to understand the behaviour of the neutron captures in the detectors. The recently collected 252Cf data and Monte Carlo simulations are studied along this thesis. The fraction of n-captures on Gadolinium (atoms loaded in the neutrino target) has been estimated to prove the time stability and consistency between detectors, and to study the behaviour of the neutron captures at the inner volume borders. These results and the performed estimation of the systematic uncertainties of the neutron capture efficiency provide a crucial input for the antineutrino oscillation analysis with two detectors.

Details

show
hide
Language(s):
 Dates: 2016
 Publication Status: Accepted / In Press
 Pages: III, 91 S.
 Publishing info: Heidelberg : Ruprecht-Karls-Universität
 Table of Contents: -
 Rev. Type: -
 Identifiers: -
 Degree: Master

Event

show

Legal Case

show

Project information

show

Source

show