  Optimized digital filtering techniques for radiation detection with HPGe detectors

Salathe, M., & Kihm, T. (2016). Optimized digital filtering techniques for radiation detection with HPGe detectors. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 808, 150-155. doi:10.1016/j.nima.2015.11.051.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
1504.02039.pdf (Preprint), 422KB
Name:
1504.02039.pdf
Beschreibung:
File downloaded from arXiv at 2016-11-07 14:38
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Salathe, M.1, Autor           
Kihm, T.2, Autor           
Affiliations:
1Division Prof. Dr. Manfred Lindner, MPI for Nuclear Physics, Max Planck Society, ou_904549              
2Division Prof. Dr. Werner Hofmann, MPI for Nuclear Physics, Max Planck Society, ou_904550              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Physics, Instrumentation and Detectors, physics.ins-det, Physics, Data Analysis, Statistics and Probability, physics.data-an
 MPINP: LHCb - Abteilung Hofmann
 Zusammenfassung: This paper describes state-of-the-art digital filtering techniques that are part of GEANA, an automatic data analysis software used for the GERDA experiment. The discussed filters include a novel, nonlinear correction method for ballistic deficits, which is combined with one of three shaping filters: a pseudo-Gaussian, a modified trapezoidal, or a modified cusp filter. The performance of the filters is demonstrated with a 762 g Broad Energy Germanium (BEGe) detector, produced by Canberra, that measures {\gamma}-ray lines from radioactive sources in an energy range between 59.5 and 2614.5 keV. At 1332.5 keV, together with the ballistic deficit correction method, all filters produce a comparable energy resolution of ~1.61 keV FWHM. This value is superior to those measured by the manufacturer and those found in publications with detectors of a similar design and mass. At 59.5 keV, the modified cusp filter without a ballistic deficit correction produced the best result, with an energy resolution of 0.46 keV. It is observed that the loss in resolution by using a constant shaping time over the entire energy range is small when using the ballistic deficit correction method.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2016-02-01
 Publikationsstatus: Online veröffentlicht
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Amsterdam : Elsevier B.V.
Seiten: - Band / Heft: 808 Artikelnummer: - Start- / Endseite: 150 - 155 Identifikator: ISSN: 0168-9002