  Characterization of nanopore electrode structures as basis for amplified electrochemical assays

Neugebauer, S., Müller, U., Lohmueller, T., Spatz, J. P., Stelzle, M., & Schuhmann, W. (2006). Characterization of nanopore electrode structures as basis for amplified electrochemical assays. Electroanalysis, 18(19-20), 1929-1936. doi:10.1002/elan.200603612.

Item is

Files

show Files
hide Files
:
Electroanalysis_18_2006_1929.pdf (Any fulltext), 577KB
 
File Permalink:
-
Name:
Electroanalysis_18_2006_1929.pdf
Description:
-
OA-Status:
Visibility:
Restricted (Max Planck Institute for Medical Research, MHMF; )
MIME-Type / Checksum:
application/pdf
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show
hide
Description:
-
OA-Status:
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Neugebauer, Sebastian, Author
Müller, Ulrich, Author
Lohmueller, Theobald1, Author           
Spatz, Joachim P.1, 2, Author           
Stelzle, Martin, Author
Schuhmann, Wolfgang, Author
Affiliations:
1Cellular Biophysics, Max Planck Institute for Medical Research, Max Planck Society, ou_2364731              
2Biophysical Chemistry, Institute of Physical Chemistry, University of Heidelberg, 69120 Heidelberg, Germany, ou_persistent22              

Content

show
hide
Free keywords: Nanopores, Nanopore electrode, Scanning electrochemical microscopy, SECM, redox cycling, Biosensors, Amplification
 Abstract: A nanopore electrode structure was fabricated consisting of ensembles of nanopores with separately addressable electrodes at the pore bottoms and the rims. A metal/insulator/metal layer structure allowed for adjusting the spacing between the bottom and rim electrodes to be in the range of about 200 nm. Pore diameters varied between 200 and 800 nm. The electrochemical properties of this electrode structure and its perspectives for applications in bioelectronics were studied using cyclic voltammetry and chronoamperometry along with high-resolution scanning electrochemical microscopy (SECM) in constant-distance mode. It was possible to visualize the electrochemical activity of a single nanometric electrode using high-resolution SECM in a combination of sample-generation-tip-collection mode and positive feedback mode. The SECM images suggested an influence of the unbiased rim electrode on redox amplification which was used as a basis for evaluating the feasibility of current amplification by means of redox cycling between the bottom and rim electrodes. Amplification factors superior to those obtained with interdigitated array electrodes could be demonstrated.

Details

show
hide
Language(s): eng - English
 Dates: 2006-06-272006-06-292006-10-19
 Publication Status: Issued
 Pages: 8
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: eDoc: 288843
DOI: 10.1002/elan.200603612
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Electroanalysis
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Weinheim, Germany : Wiley-VCH
Pages: - Volume / Issue: 18 (19-20) Sequence Number: - Start / End Page: 1929 - 1936 Identifier: ISSN: 1040-0397
CoNE: https://pure.mpg.de/cone/journals/resource/954925587333