日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

登録内容を編集ファイル形式で保存
 
 
ダウンロード電子メール
  Characterization of nanopore electrode structures as basis for amplified electrochemical assays

Neugebauer, S., Müller, U., Lohmueller, T., Spatz, J. P., Stelzle, M., & Schuhmann, W. (2006). Characterization of nanopore electrode structures as basis for amplified electrochemical assays. Electroanalysis, 18(19-20), 1929-1936. doi:10.1002/elan.200603612.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル
非表示: ファイル
:
Electroanalysis_18_2006_1929.pdf (全文テキスト(全般)), 577KB
 
ファイルのパーマリンク:
-
ファイル名:
Electroanalysis_18_2006_1929.pdf
説明:
-
OA-Status:
閲覧制限:
制限付き (Max Planck Institute for Medical Research, MHMF; )
MIMEタイプ / チェックサム:
application/pdf
技術的なメタデータ:
著作権日付:
-
著作権情報:
-
CCライセンス:
-

関連URL

表示:
非表示:
説明:
-
OA-Status:
URL:
https://dx.doi.org/10.1002/elan.200603612 (全文テキスト(全般))
説明:
-
OA-Status:

作成者

表示:
非表示:
 作成者:
Neugebauer, Sebastian, 著者
Müller, Ulrich, 著者
Lohmueller, Theobald1, 著者           
Spatz, Joachim P.1, 2, 著者           
Stelzle, Martin, 著者
Schuhmann, Wolfgang, 著者
所属:
1Cellular Biophysics, Max Planck Institute for Medical Research, Max Planck Society, ou_2364731              
2Biophysical Chemistry, Institute of Physical Chemistry, University of Heidelberg, 69120 Heidelberg, Germany, ou_persistent22              

内容説明

表示:
非表示:
キーワード: Nanopores, Nanopore electrode, Scanning electrochemical microscopy, SECM, redox cycling, Biosensors, Amplification
 要旨: A nanopore electrode structure was fabricated consisting of ensembles of nanopores with separately addressable electrodes at the pore bottoms and the rims. A metal/insulator/metal layer structure allowed for adjusting the spacing between the bottom and rim electrodes to be in the range of about 200 nm. Pore diameters varied between 200 and 800 nm. The electrochemical properties of this electrode structure and its perspectives for applications in bioelectronics were studied using cyclic voltammetry and chronoamperometry along with high-resolution scanning electrochemical microscopy (SECM) in constant-distance mode. It was possible to visualize the electrochemical activity of a single nanometric electrode using high-resolution SECM in a combination of sample-generation-tip-collection mode and positive feedback mode. The SECM images suggested an influence of the unbiased rim electrode on redox amplification which was used as a basis for evaluating the feasibility of current amplification by means of redox cycling between the bottom and rim electrodes. Amplification factors superior to those obtained with interdigitated array electrodes could be demonstrated.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2006-06-272006-06-292006-10-19
 出版の状態: 出版
 ページ: 8
 出版情報: -
 目次: -
 査読: 査読あり
 識別子(DOI, ISBNなど): eDoc: 288843
DOI: 10.1002/elan.200603612
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Electroanalysis
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: Weinheim, Germany : Wiley-VCH
ページ: - 巻号: 18 (19-20) 通巻号: - 開始・終了ページ: 1929 - 1936 識別子(ISBN, ISSN, DOIなど): ISSN: 1040-0397
CoNE: https://pure.mpg.de/cone/journals/resource/954925587333