English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Small molecule detection by reflective interferometric fourier transform spectroscopy (RIFTS)

Pacholski, C., Perelman, L. A., VanNieuwenhze, M. S., & Sailor, M. J. (2009). Small molecule detection by reflective interferometric fourier transform spectroscopy (RIFTS). Physica Status Solidi A, 206(6), 1318-1321. doi:10.1002/pssa.200881072.

Item is

Files

show Files
hide Files
:
PhysStatusSolidiA_206_2009_1318.pdf (Any fulltext), 279KB
 
File Permalink:
-
Name:
PhysStatusSolidiA_206_2009_1318.pdf
Description:
-
OA-Status:
Visibility:
Restricted (Max Planck Institute for Medical Research, MHMF; )
MIME-Type / Checksum:
application/pdf
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show
hide
Description:
-
OA-Status:
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Pacholski, Claudia1, 2, Author           
Perelman, Loren A., Author
VanNieuwenhze, Michael S., Author
Sailor, Michael J., Author
Affiliations:
1Cellular Biophysics, Max Planck Institute for Medical Research, Max Planck Society, ou_2364731              
2Biophysical Chemistry, Institute of Physical Chemistry, University of Heidelberg, 69120 Heidelberg, Germany, ou_persistent22              

Content

show
hide
Free keywords: 42.70.Qs; 42.79.Pw; 87.85.fk
 Abstract: A new method for the compensation of matrix effects in biosensing experiments referred to as reflective interferometric Fourier transform spectroscopy (RIFTS) has been developed recently [1]. It employs a porous silicon sensor comprised of two porous silicon layers stacked one on top of the other. The structure has a complicated reflectivity spectrum that can be resolved by FFT analysis leading to three distinctive peaks which are assigned to the layers in the porous silicon structur. If the double layer is appropriately designed, the bottom layer can act as a reference channel. In this paper the specific sensing of small molecules using RIFTS is demonstrated for the first time. Ac-L-Lys-D-Ala-D-Ala has been immobilized to the sensor surface representing the capture probe and vancomycin was used as target analyte.

Details

show
hide
Language(s): eng - English
 Dates: 2008-03-202008-11-252009-03-252009
 Publication Status: Issued
 Pages: 4
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1002/pssa.200881072
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Physica Status Solidi A
  Other : Physica Status Solidi A: Applications and Materials Science
  Abbreviation : Phys. Stat. Sol. (a)
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Weinheim : Wiley-VCH
Pages: - Volume / Issue: 206 (6) Sequence Number: - Start / End Page: 1318 - 1321 Identifier: ISSN: 1862-6300
CoNE: https://pure.mpg.de/cone/journals/resource/1862630