English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Soft tissue influence on ex vivo mobility in the hip of Iguana: Comparison with in vivo movement and its bearing on joint motion of fossil sprawling tetrapods

Arnold, P., Fischer, M. S., & Nyakatura, J. A. (2014). Soft tissue influence on ex vivo mobility in the hip of Iguana: Comparison with in vivo movement and its bearing on joint motion of fossil sprawling tetrapods. Journal of Anatomy, 225(1), 31-41. doi:10.1111/joa.12187.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Arnold, Patrick1, Author           
Fischer, Martin S., Author
Nyakatura, John A., Author
Affiliations:
1external, ou_persistent22              

Content

show
hide
Free keywords: Dissection, Green iguana, Hip joint, Iguana iguana, Joints (Anatomy) -- Range of motion, limb kinematics, range of mobility, range of motion, soft tissue influence, sprawling gait, Tetrapods, XROMM
 Abstract: The reconstruction of a joint's maximum range of mobility ( ROM) often is a first step when trying to understand the locomotion of fossil tetrapods. But previous studies suggest that the ROM of a joint is restricted by soft tissues surrounding the joint. To expand the limited informative value of ROM studies for the reconstruction of a fossil species' locomotor characteristics, it is moreover necessary to better understand the relationship of ex vivo ROM with the actual in vivo joint movement. To gain insight into the relationship between ex vivo mobility and in vivo movement, we systematically tested for the influence of soft tissues on joint ROM in the hip of the modern lizard Iguana iguana. Then, we compared the ex vivo mobility to in vivo kinematics of the hip joint in the same specimens using X-ray sequences of steady-state treadmill locomotion previously recorded. With stepwise removal of soft tissues and a repeated-measurement protocol, we show that soft tissues surrounding the hip joint considerably limit ROM, highlighting the problems when joint ROM is deduced from bare bones only. We found the integument to have the largest effect on the range of long-axis rotation, pro- and retraction. Importantly, during locomotion the iguana used only a fragment of the ROM that was measured in our least restrictive dissection situation (i.e. pelvis and femur only conjoined by ligaments), demonstrating the discrepancy between hip joint ROM and actual in vivo movement. Our study emphasizes the necessity for caution when attempting to reconstruct joint ROM or even locomotor kinematics from fossil bones only, as actual in vivo movement cannot be deduced directly from any condition of cadaver mobility in Iguana and likely in other tetrapods.

Details

show
hide
Language(s): eng - English
 Dates: 2014
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1111/joa.12187
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Journal of Anatomy
  Alternative Title : Journal of Anatomy
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 225 (1) Sequence Number: - Start / End Page: 31 - 41 Identifier: ISBN: 00218782