English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Thermodynamic correction of particle concentrations measured by underwing probes on fast-flying aircraft

Weigel, R., Spichtinger, P., Mahnke, C., Klingebiel, M., Afchine, A., Petzold, A., et al. (2016). Thermodynamic correction of particle concentrations measured by underwing probes on fast-flying aircraft. Atmospheric Measurement Techniques, 9(10), 5135-5162. doi:10.5194/amt-9-5135-2016.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Weigel, Ralf1, Author
Spichtinger, Peter1, Author
Mahnke, Christoph1, Author
Klingebiel, M.2, Author           
Afchine, Armin1, Author
Petzold, Andreas1, Author
Kraemer, Martina1, Author
Costa, Anja1, Author
Molleker, S.2, Author           
Reutter, Philipp1, Author
Szakall, Miklos1, Author
Port, Max1, Author
Grulich, Lucas1, Author
Jurkat, Tina1, Author
Minikin, Andreas1, Author
Borrmann, S.2, Author           
Affiliations:
1external, ou_persistent22              
2Particle Chemistry, Max Planck Institute for Chemistry, Max Planck Society, ou_1826291              

Content

show
hide
Free keywords: -
 Abstract: Particle concentration measurements with underwing probes on aircraft are impacted by air compression upstream of the instrument body as a function of flight velocity. In particular, for fast-flying aircraft the necessity arises to account for compression of the air sample volume. Hence, a correction procedure is needed to invert measured particle number concentrations to ambient conditions that is commonly applicable to different instruments to gain comparable results. In the compression region where the detection of particles occurs ( i.e. under factual measurement conditions), pressure and temperature of the air sample are increased compared to ambient ( undisturbed) conditions in certain distance away from the aircraft. Conventional procedures for scaling the measured number densities to ambient conditions presume that the air volume probed per time interval is determined by the aircraft speed ( true air speed, TAS). However, particle imaging instruments equipped with pitot tubes measuring the probe air speed ( PAS) of each underwing probe reveal PAS values systematically below those of the TAS. We conclude that the deviation between PAS and TAS is mainly caused by the compression of the probed air sample. From measurements during two missions in 2014 with the German Gulfstream G-550 ( HALO - High Altitude LOng range) research aircraft we develop a procedure to correct the measured particle concentration to ambient conditions using a thermodynamic approach. With the provided equation, the corresponding concentration correction factor xi is applicable to the high-frequency measurements of the underwing probes, each of which is equipped with its own air speed sensor ( e.g. a pitot tube). xi values of 1 to 0.85 are calculated for air speeds ( i.e. TAS) between 60 and 250 ms(-1). For different instruments at individual wing position the calculated xi values exhibit strong consistency, which allows for a parameterisation of xi as a function of TAS for the current HALO underwing probe configuration. The ability of cloud particles to adopt changes of air speed between ambient and measurement conditions depends on the cloud particles' inertia as a function of particle size ( diameter D-p). The suggested inertia correction factor mu ( D-p) for liquid cloud drops ranges between 1 ( for D-p < 70 mu m) and 0.8 ( for 100 mu m < D-p < 225 mu m) but it needs to be applied carefully with respect to the particles' phase and nature. The correction of measured concentration by both factors, xi and mu ( D-p), yields higher ambient particle concentration by about 10-25% compared to conventional procedures - an improvement which can be considered as significant for many research applications. The calculated xi values are specifically related to the considered HALO underwing probe arrangement and may differ for other air-craft. Moreover, suggested corrections may not cover all impacts originating from high flight velocities and from interferences between the instruments and e.g. the aircraft wings and/or fuselage. Consequently, it is important that PAS ( as a function of TAS) is individually measured by each probe deployed underneath the wings of a fast-flying aircraft.

Details

show
hide
Language(s):
 Dates: 2016
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: ISI: 000386666200001
DOI: 10.5194/amt-9-5135-2016
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Atmospheric Measurement Techniques
  Abbreviation : AMT
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Göttingen : European Geosciences Union, Copernicus
Pages: - Volume / Issue: 9 (10) Sequence Number: - Start / End Page: 5135 - 5162 Identifier: Other: 1867-1381
CoNE: https://pure.mpg.de/cone/journals/resource/1867-1381