  Beating the standard sensitivity-bandwidth limit of cavity-enhanced interferometers with internal squeezed-light generation

Korobko, M., Kleybolte, L., Ast, S., Miao, H., Chen, Y., & Schnabel, R. (2017). Beating the standard sensitivity-bandwidth limit of cavity-enhanced interferometers with internal squeezed-light generation. Physical Review Letters, 118: 143601. doi:10.1103/PhysRevLett.118.143601.

Item is

Files

show Files
hide Files
:
1702.01044.pdf (Preprint), 2MB
Name:
1702.01044.pdf
Description:
File downloaded from arXiv at 2017-03-14 11:11
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
:
PRL118.143601.pdf (Publisher version), 667KB
 
File Permalink:
-
Name:
PRL118.143601.pdf
Description:
-
OA-Status:
Visibility:
Restricted (Max Planck Institute for Gravitational Physics (Albert Einstein Institute), MPGR; )
MIME-Type / Checksum:
application/pdf
Technical Metadata:
Copyright Date:
-
Copyright Info:
American Physical Society
License:
-

Locators

show

Creators

show
hide
 Creators:
Korobko, Mikhail, Author
Kleybolte, Lisa, Author
Ast, Stefan1, Author           
Miao, Haixing, Author
Chen, Yanbei, Author
Schnabel, Roman, Author
Affiliations:
1Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society, ou_24010              

Content

show
hide
Free keywords: Quantum Physics, quant-ph,General Relativity and Quantum Cosmology, gr-qc
 Abstract: The shot-noise limited peak sensitivity of cavity-enhanced interferometric measurement devices, such as gravitational-wave detectors, can be improved by increasing the cavity finesse, even when comparing fixed intra-cavity light powers. For a fixed light power inside the detector, this comes at the price of a proportional reduction in the detection bandwidth. High sensitivity over a large span of signal frequencies, however, is essential for astronomical observations. It is possible to overcome this standard sensitivity-bandwidth limit using non-classical correlations in the light field. Here, we investigate the internal squeezing approach, where the parametric amplification process creates a non-classical correlation directly inside the interferometer cavity. We analyse the limits of the approach theoretically, and measure 36% increase in the sensitivity-bandwidth product compared to the classical case. To our knowledge this is the first experimental demonstration of an improvement in the sensitivity-bandwidth product using internal squeezing, opening the way for a new class of optomechanical force sensing devices.

Details

show
hide
Language(s):
 Dates: 2017-02-032017-02-132017
 Publication Status: Issued
 Pages: 5 pages, 3 figures
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Physical Review Letters
  Abbreviation : Phys. Rev. Lett.
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Woodbury, N.Y. : American Physical Society
Pages: - Volume / Issue: 118 Sequence Number: 143601 Start / End Page: - Identifier: ISSN: 0031-9007
CoNE: https://pure.mpg.de/cone/journals/resource/954925433406_1