日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

登録内容を編集ファイル形式で保存
 
 
ダウンロード電子メール
  Subtomogram analysis using the Volta phase plate

Khoshouei, M., Pfeffer, S., Baumeister, W., Förster, F., & Danev, R. (2017). Subtomogram analysis using the Volta phase plate. Journal of Structural Biology, 197(2), 94-101. doi:10.1016/j.jsb.2016.05.009.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

作成者

表示:
非表示:
 作成者:
Khoshouei, Maryam1, 著者           
Pfeffer, Stefan1, 著者           
Baumeister, Wolfgang1, 著者           
Förster, Friedrich1, 著者           
Danev, Radostin1, 著者           
所属:
1Baumeister, Wolfgang / Molecular Structural Biology, Max Planck Institute of Biochemistry, Max Planck Society, ou_1565142              

内容説明

表示:
非表示:
キーワード: BIOLOGY IN-SITU; ANGSTROM RESOLUTION; CRYOELECTRON TOMOGRAPHY; CRYSTAL-STRUCTURE; CRYO-EM; ELECTRON CRYOTOMOGRAPHY; EUKARYOTIC RIBOSOME; BACTERIAL; ORGANIZATION; COMPLEXBiochemistry & Molecular Biology; Biophysics; Cell Biology; Ciyo-electron tomography; Subtomogram analysis; Volta phase plate; Ribosome;
 要旨: Cryo-electron tomography (CET) and subtomogram analysis allow studying the structures of macro molecular complexes in their natural context. The radiation sensitivity of vitrified biological specimens and the resulting low signal-to-noise ratio (SNR) in CET limit the amount of structural information that can be mined from tomographic data. The Volta phase plate (VPP) has emerged as an effective means to increase the SNR and hence contrast compared to 'conventional' defocus-based phase contrast transmission electron microscopy (CTEM). Here, we assess the performance of the VPP compared to CTEM in subtomogram analysis, using the mammalian 80S ribosome as a test case. Accurate focusing is the major factor for achieving high resolution with the VPP, as highlighted by a comparison of slightly different focusing strategies. From only 1400 subtomograms, the VPP yields a subtomogram average of the mammalian 80S ribosome at 9.6 angstrom resolution without laborious contrast transfer function (CTF) correction. The subtomogram averages obtained using CTEM approaches are comparable, but suffer from lower signal transfer in certain frequency bands due to the oscillations of the CTF. Our study demonstrates that the VPP is a valuable tool for subtomogram analysis, because it enables improved performance and efficiency in terms of structure localization and number of subtomograms required for a given resolution. (C) 2016 Elsevier Inc. All rights reserved.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2016-05-252017-02
 出版の状態: 出版
 ページ: 8
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): ISI: 000393268200004
DOI: 10.1016/j.jsb.2016.05.009
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示: 非表示:
Project name : German Research Council (DFG 716/4-1)
Grant ID : -
Funding program : -
Funding organization : -

出版物 1

表示:
非表示:
出版物名: Journal of Structural Biology
  省略形 : J. Struct. Biol.
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: Orlando, Fla. : Academic Press
ページ: - 巻号: 197 (2) 通巻号: - 開始・終了ページ: 94 - 101 識別子(ISBN, ISSN, DOIなど): ISSN: 1047-8477
CoNE: https://pure.mpg.de/cone/journals/resource/954922650160