Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Low-dose fixed-target serial synchrotron crystallography

Owen, R. L., Axford, D., Sherrell, D. A., Kuo, A., Ernst, O. P., Schulz, E.-C., et al. (2017). Low-dose fixed-target serial synchrotron crystallography. Acta Crystallographica Section D: Structural Biology, 73, 373-378. doi:10.1107/S2059798317002996.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
Low-dose fixed-target serial synchrotron crystallography.pdf (Verlagsversion), 2MB
Name:
Low-dose fixed-target serial synchrotron crystallography.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
2017-04-01
Copyright Info:
Owen et. al.

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Owen, Robin L.1, Autor
Axford, Danny1, Autor
Sherrell, Darren A.1, Autor
Kuo, Anling2, Autor
Ernst, Oliver P.2, 3, Autor
Schulz, Eike-Christian4, Autor           
Miller, R. J. Dwayne4, 5, Autor           
Müller-Werkmeister, Henrike4, Autor           
Affiliations:
1Diamond Light Source, Harwell Science and Innovation Campus, Didcot OX11 0DE, England, ou_persistent22              
2Department of Biochemistry, University of Toronto, King's College Circle , Toronto, Ontario M5S 1A8, Canada, , ou_persistent22              
3Department of Molecular Genetics, University of Toronto, King's College Circle, Toronto, Ontario M5S 1A8, Canada, ou_persistent22              
4Miller Group, Atomically Resolved Dynamics Department, Max Planck Institute for the Structure and Dynamics of Matter, Max Planck Society, ou_1938288              
5Departments of Chemistry and Physics, University of Toronto, King's College Circle, Toronto, Ontario M5S 1A8, Canada, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: macromolecular crystallography serial synchrotron crystallography fixed target room-temperature crystallography crystallography on a chip low dose
 Zusammenfassung: The development of serial crystallography has been driven by the sample requirements imposed by X-ray free-electron lasers. Serial techniques are now being exploited at synchrotrons. Using a fixed-target approach to high-throughput serial sampling, it is demonstrated that high-quality data can be collected from myoglobin crystals, allowing room-temperature, low-dose structure determination. The combination of fixed-target arrays and a fast, accurate translation system allows high-throughput serial data collection at high hit rates and with low sample consumption.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2016-10-202017-02-222017-04-01
 Publikationsstatus: Online veröffentlicht
 Seiten: 6
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1107/S2059798317002996
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Acta Crystallographica Section D: Structural Biology
  Kurztitel : Acta Cryst. D
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Chester, England : International Union of Crystallography
Seiten: 6 Band / Heft: 73 Artikelnummer: - Start- / Endseite: 373 - 378 Identifikator: ISSN: 2059-7983
CoNE: https://pure.mpg.de/cone/journals/resource/2059-7983