日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  Miniaturized electroencephalographic scalp electrode for optimal wearing comfort

Nikulin, V. V., Kegeles, J., & Curio, G. (2010). Miniaturized electroencephalographic scalp electrode for optimal wearing comfort. Clinical Neurophysiology, 121(7), 1007-1014. doi:10.1016/j.clinph.2010.02.008.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Nikulin, Vadim V.1, 著者           
Kegeles, Jewgeni, 著者
Curio, Gabriel, 著者
所属:
1External Organizations, ou_persistent22              

内容説明

表示:
非表示:
キーワード: Electrode; EEG; Cortex; Humans; Brain–computer interface; Oscillations
 要旨: Objective Current mainstream EEG electrode setups permit efficient recordings, but are often bulky and uncomfortable for subjects. Here we introduce a novel type of EEG electrode, which is designed for an optimal wearing comfort. The electrode is referred to as C-electrode where “C” stands for comfort. Methods The C-electrode does not require any holder/cap for fixation on the head nor does it use traditional pads/lining of disposable electrodes – thus, it does not disturb subjects. Fixation of the C-electrode on the scalp is based entirely on the adhesive interaction between the very light C-electrode/wire construction (<35 mg) and a droplet of EEG paste/gel. Moreover, because of its miniaturization, both C-electrode (diameter 2–3 mm) and a wire (diameter ∼50 μm) are minimally (or not at all) visible to an external observer. EEG recordings with standard and C-electrodes were performed during rest condition, self-paced movements and median nerve stimulation. Results The quality of EEG recordings for all three types of experimental conditions was similar for standard and C-electrodes, i.e., for near-DC recordings (Bereitschaftspotential), standard rest EEG spectra (1–45 Hz) and very fast oscillations ∼600 Hz (somatosensory evoked potentials). The tests showed also that once being placed on a subject’s head, C-electrodes can be used for 9 h without any loss in EEG recording quality. Furthermore, we showed that C-electrodes can be effectively utilized for Brain-Computer Interfacing. C-electrodes proved to posses a high stability of mechanical fixation (stayed attached with 2.5 g accelerations). Subjects also reported not having any tactile sensations associated with wearing of C-electrodes. Conclusion C-electrodes provide optimal wearing comfort without any loss in the quality of EEG recordings. Significance We anticipate that C-electrodes can be used in a wide range of clinical, research and emerging neuro-technological environments.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2010-02-012010-03-152010-07
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): DOI: 10.1016/j.clinph.2010.02.008
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Clinical Neurophysiology
  その他 : Clin. Neurophysiol.
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: Amsterdam : Elsevier
ページ: - 巻号: 121 (7) 通巻号: - 開始・終了ページ: 1007 - 1014 識別子(ISBN, ISSN, DOIなど): ISSN: 1388-2457
CoNE: https://pure.mpg.de/cone/journals/resource/954926941726