English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Combining sparsity and rotational invariance in EEG/MEG source reconstruction

Haufe, S., Nikulin, V. V., Ziehe, A., Müller, K.-R., & Nolte, G. (2008). Combining sparsity and rotational invariance in EEG/MEG source reconstruction. NeuroImage, 42(2), 726-738. doi:10.1016/j.neuroimage.2008.04.246.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Haufe, Stefan, Author
Nikulin, Vadim V.1, Author           
Ziehe, Andreas, Author
Müller, Klaus-Robert, Author
Nolte, Guido, Author
Affiliations:
1External Organizations, ou_persistent22              

Content

show
hide
Free keywords: EEG/MEG; Inverse problem; Source localization; Second-order cone programming; ℓ1-norm Regularization; Sparsity; Vector fields; Rotational invariance
 Abstract: We introduce Focal Vector Field Reconstruction (FVR), a novel technique for the inverse imaging of vector fields. The method was designed to simultaneously achieve two goals: a) invariance with respect to the orientation of the coordinate system, and b) a preference for sparsity of the solutions and their spatial derivatives. This was achieved by defining the regulating penalty function, which renders the solutions unique, as a global ℓ1-norm of local ℓ2-norms. We show that the method can be successfully used for solving the EEG inverse problem. In the joint localization of 2–3 simulated dipoles, FVR always reliably recovers the true sources. The competing methods have limitations in distinguishing close sources because their estimates are either too smooth (LORETA, Minimum ℓ1-norm) or too scattered (Minimum ℓ2-norm). In both noiseless and noisy simulations, FVR has the smallest localization error according to the Earth Mover's Distance (EMD), which is introduced here as a meaningful measure to compare arbitrary source distributions. We also apply the method to the simultaneous localization of left and right somatosensory N20 generators from real EEG recordings. Compared to its peers FVR was the only method that delivered correct location of the source in the somatosensory area of each hemisphere in accordance with neurophysiological prior knowledge.

Details

show
hide
Language(s): eng - English
 Dates: 2008-04-032008-02-282008-04-142008-05-032008-08-15
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1016/j.neuroimage.2008.04.246
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: NeuroImage
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Orlando, FL : Academic Press
Pages: - Volume / Issue: 42 (2) Sequence Number: - Start / End Page: 726 - 738 Identifier: ISSN: 1053-8119
CoNE: https://pure.mpg.de/cone/journals/resource/954922650166