日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  The Electron Capture in 163Ho Experiment ECHo

Gastaldo, L., Blaum, K., Chrysalidis, K., Goodacre, T. D., Domula, A., Door, M., Dorrer, H., Düllmann, C., Eberhardt, K., Eliseev, S., Enss, C., Faessler, A., Filianin, P., Fleischmann, A., Fonnesu, D., Gamer, L., Haas, R., Hassel, C., Hengstler, D., Jochum, J., Johnston, K., Kebschull, U., Kempf, S., Kieck, T., Köster, U., Lahiri, S., Maiti, M., Mantegazzini, F., Marsh, B., Neroutsos, P., Novikov, Y. N., Ranitzsch, P., Rothe, S., Rischka, A., Saenz, A., Sander, O., Schneider, F., Scholl, S., Schüssler, R., Schweiger, C., Simkovic, F., Stora, T., Szücs, Z., Türler, A., Veinhard, M., Weber, M., Wegner, M., Wendt, K., & Zuber, K. (2017). The Electron Capture in 163Ho Experiment ECHo. European Physical Journal - Special Topics, 226(8), 1623-1694. doi:10.1140/epjst/e2017-70071-y.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Gastaldo, L.1, 著者
Blaum, Klaus2, 著者           
Chrysalidis, K.1, 著者
Goodacre, T. Day1, 著者
Domula, A.1, 著者
Door, Menno2, 著者           
Dorrer, H.1, 著者
Düllmann, Ch.E.1, 著者
Eberhardt, K.1, 著者
Eliseev, Sergey2, 著者           
Enss, C.1, 著者
Faessler, A.1, 著者
Filianin, Pavel2, 著者           
Fleischmann, A.1, 著者
Fonnesu, D.1, 著者
Gamer, L.1, 著者
Haas, R.1, 著者
Hassel, C.1, 著者
Hengstler, D.1, 著者
Jochum, J.1, 著者
Johnston, K.1, 著者Kebschull, U.1, 著者Kempf, S.1, 著者Kieck, T.1, 著者Köster, U.1, 著者Lahiri, S.1, 著者Maiti, M.1, 著者Mantegazzini, F.1, 著者Marsh, B.1, 著者Neroutsos, P.1, 著者Novikov, Yuri N.2, 著者           Ranitzsch, P.C.O.1, 著者Rothe, S.1, 著者Rischka, Alexander2, 著者           Saenz, A.1, 著者Sander, O.1, 著者Schneider, F.1, 著者Scholl, S.1, 著者Schüssler, Rima2, 著者           Schweiger, Christoph2, 著者           Simkovic, F.1, 著者Stora, T.1, 著者Szücs, Z.1, 著者Türler, A.1, 著者Veinhard, M.1, 著者Weber, M.1, 著者Wegner, M.1, 著者Wendt, K.1, 著者Zuber, K.1, 著者 全て表示
所属:
11.Kirchhoff Institute for Physics, Heidelberg University, HeidelbergGermany 2.Max-Planck Institute for Nuclear Physics Heidelberg Germany 3.Institute for Physics, Johannes Gutenberg-UniversityMainzGermany 4.ISOLDE, CERN Geneve Switzerland 5.Institute for Nuclear and Particle PhysicsTU Dresden Germany 6.Institute for Nuclear Chemistry, Johannes Gutenberg University Mainz Germany 7.Laboratory of Radiochemistry and Environmental Chemistry, Department Biology and Chemistry, Paul Scherrer InstituteVilligen PSI Switzerland 8.Laboratory of Radiochemistry and Environmental Chemistry, Department of Chemistry and Biochemistry, University of Bern Bern Switzerland 9.GSI Helmholtzzentrum für Schwerionenforschung Darmstadt Germany 10.Helmholtz Institute Mainz Mainz Germany 11.Institute for Theoretical Physics, University of Tübingen Tübingen Germany 12.Physics Institute, University of Tübingen Germany 13.Goethe-Universität Frankfurt am Main Germany 14.Institut Laue-Langevin Grenoble France 15.Chemical Sciences Division, Saha Institute of Nuclear Physics, 1/AF Bidhannagar Kolkata India 16.Department of PhysicsIndian Institute of Technology Roorkee Roorkee India 17.Petersburg Nuclear Physics Institute Gatchina Russia 18. St.Petersburg State University St. Petersburg Russia 19.Institut für Physik, Humboldt-Universität zu Berlin Berlin Germany 20. Karlsruhe Institute of Technology, Institute for Data Processing and Electronics Karlsruhe Germany , ou_persistent22              
2Division Prof. Dr. Klaus Blaum, MPI for Nuclear Physics, Max Planck Society, ou_904548              

内容説明

表示:
非表示:
キーワード: -
 MPINP: Präzisionsexperimente - Abteilung Blaum
 要旨: Neutrinos, and in particular their tiny but non-vanishing masses, can be considered one of the doors towards physics beyond the Standard Model. Precision measurements of the kinematics of weak interactions, in particular of the 3H β-decay and the 163Ho electron capture (EC), represent the only model independent approach to determine the absolute scale of neutrino masses. The electron capture in 163Ho experiment, ECHo, is designed to reach sub-eV sensitivity on the electron neutrino mass by means of the analysis of the calorimetrically measured electron capture spectrum of the nuclide 163Ho. The maximum energy available for this decay, about 2.8 keV, constrains the type of detectors that can be used. Arrays of low temperature metallic magnetic calorimeters (MMCs) are being developed to measure the 163Ho EC spectrum with energy resolution below 3 eV FWHM and with a time resolution below 1 μs. To achieve the sub-eV sensitivity on the electron neutrino mass, together with the detector optimization, the availability of large ultra-pure 163Ho samples, the identification and suppression of background sources as well as the precise parametrization of the 163Ho EC spectrum are of utmost importance. The high-energy resolution 163Ho spectra measured with the first MMC prototypes with ion-implanted 163Ho set the basis for the ECHo experiment. We describe the conceptual design of ECHo and motivate the strategies we have adopted to carry on the present medium scale experiment, ECHo-1K. In this experiment, the use of 1 kBq 163Ho will allow to reach a neutrino mass sensitivity below 10 eV/c2. We then discuss how the results being achieved in ECHo-1k will guide the design of the next stage of the ECHo experiment, ECHo-1M, where a source of the order of 1 MBq 163Ho embedded in large MMCs arrays will allow to reach sub-eV sensitivity on the electron neutrino mass.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2017-06-22
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: 査読あり
 識別子(DOI, ISBNなど): DOI: 10.1140/epjst/e2017-70071-y
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: European Physical Journal - Special Topics
  省略形 : Eur. Phys. J. Spec. Top.
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: Berlin, Heidelberg : Springer
ページ: - 巻号: 226 (8) 通巻号: - 開始・終了ページ: 1623 - 1694 識別子(ISBN, ISSN, DOIなど): ISSN: 1951-6355
CoNE: https://pure.mpg.de/cone/journals/resource/1000000000277330